title: "Sulfur Dioxide (SO₂) Sensors & Limit Values | Aethair"
description: "Sulfur dioxide (SO₂) is a colorless gas with a sharp odor, produced by burning sulfur-containing fuels. See EPA, WHO, and EU limits and SO₂ monitors."
url: https://aethair.io/parameters/so2/
---

Measurements · Gases & VOCs

# Sulfur Dioxide (SO₂)

Also known as sulphur dioxide

Sulfur dioxide: a criteria pollutant from fossil-fuel combustion that irritates the respiratory system.

[Schedule a call](https://calendly.com/d/ctdd-mkr-v9v/aethair-demo-website) [Configure Sulfur Dioxide (SO₂) Monitoring](https://aethair.io/build/?params=so2)

At a glance

ppm Gases & VOCs

2 ways to measure it

- **Aethair PRO** 2 cartridges
- **Thiamis** 2 external instruments

9 standards set limits

- [EPA EPA NAAQS](https://aethair.io/standards/epa_naaqs/)
- [WHO WHO 2021](https://aethair.io/standards/who_aqg_2021/)
- [OSHA OSHA PEL](https://aethair.io/resources/osha-air-quality-standards-compliance/)
- [ACGIH ACGIH TLV](https://aethair.io/standards/acgih_tlv/)
- [EU EU 2024/2881](https://aethair.io/standards/eu_aaqd_2024/)
- [AQMD SCAQMD 1180](https://aethair.io/standards/scaqmd_1180/)
- [NIOSH NIOSH REL](https://aethair.io/standards/niosh_rel/)
- [OSHA OSHA construction](https://aethair.io/standards/osha_construction_pel/)
- [CAL Cal/OSHA PEL](https://aethair.io/standards/cal_osha_pel/)

What it is

## What is sulfur dioxide (SO₂)?

Sulfur dioxide is a colorless gas with a sharp, pungent odor, produced by burning fuels that contain sulfur and by certain industrial processes. Its dominant sources are coal and oil combustion in power generation and heavy industry, metal smelting, oil refining, and, at sea, ships burning high-sulfur fuel. In the atmosphere, SO₂ oxidizes to form sulfate particles and contributes to acid rain, so its impact reaches beyond the gas itself into secondary particulate matter and ecosystem damage. It is one of the six ambient criteria pollutants.

Because its sources are concentrated around industry and shipping, SO₂ is especially relevant to monitoring near power plants, refineries, smelters, and ports.

### Health and operational effects

SO₂ irritates the airways and can cause bronchoconstriction, particularly in people with asthma, for whom even short exposures during exercise can trigger symptoms. Longer-term and community exposure is associated with respiratory illness and, through the sulfate particles it forms, with the broader health burden of fine particulate matter. Its environmental effects (acid deposition harming soils, waters, and buildings) drove some of the earliest air-pollution regulation and continue to shape fuel-sulfur limits worldwide.

For industrial operators, port authorities, and regulators, SO₂ is both a directly regulated pollutant and a marker of sulfur-fuel combustion.

Limits

## Sulfur Dioxide (SO₂) Limit Values

The published values, by averaging period; each links to the standard that sets it.

Annual

[**20 µg/m³** EU 2024/2881](https://aethair.io/standards/eu_aaqd_2024/ "new annual limit value (2030)")

24-hour

[**40 µg/m³** WHO 2021](https://aethair.io/standards/who_aqg_2021/) [**50 µg/m³** EU 2024/2881](https://aethair.io/standards/eu_aaqd_2024/ "2030 limit value")

8-hour TWA

[**5 ppm** OSHA PEL](https://aethair.io/resources/osha-air-quality-standards-compliance/) [**5 ppm** OSHA construction](https://aethair.io/standards/osha_construction_pel/)

8-hour TWA (PEL)

[**2 ppm** Cal/OSHA PEL](https://aethair.io/standards/cal_osha_pel/)

1-hour

[**75 ppb** EPA NAAQS](https://aethair.io/standards/epa_naaqs/)

1-hour, notification threshold

[**75 ppb** SCAQMD 1180](https://aethair.io/standards/scaqmd_1180/)

STEL

[**0.25 ppm** ACGIH TLV](https://aethair.io/standards/acgih_tlv/) [**5 ppm** NIOSH REL](https://aethair.io/standards/niosh_rel/) [**5 ppm** Cal/OSHA PEL](https://aethair.io/standards/cal_osha_pel/)

TWA

[**2 ppm** NIOSH REL](https://aethair.io/standards/niosh_rel/)

- **EU 2024/2881** 20 µg/m³: new annual limit value (2030)
- **EU 2024/2881** 50 µg/m³: 2030 limit value

SO₂ is reported in ppb or µg/m³ and compared as 1-hour, 24-hour, or annual averages, depending on the framework. The US EPA NAAQS, the WHO 2021 guideline, and the EU's new 2030 limit values (which add an annual limit) all appear in the table on this page, alongside occupational limits for workplace exposure. Because health effects include short-term bronchoconstriction, the short-averaging-period values matter as much as the annual ones, and a high 1-hour reading near a source is the compliance-relevant event.

Methods and guidance

[BAAQMD 12-15](https://aethair.io/standards/baaqmd_12_15/)

How it is measured

## How Sulfur Dioxide (SO₂) Is Measured

Reference-grade ambient monitoring uses **UV fluorescence analyzers**, which excite SO₂ molecules with ultraviolet light and measure the fluorescence they emit, a selective, sensitive, and stable method that underpins regulatory networks. For distributed and lower-cost monitoring, **electrochemical sensors** give real-time SO₂ readings but require compensation for temperature, humidity, and cross-sensitivity to other gases, and benefit from co-location against a reference for correction. Around industrial sources, fixed monitors track fence-line concentrations with wind data for source attribution.

Aethair PRO cartridges 2

A pre-calibrated cartridge in one of Aethair PRO's sockets: Aethair MultiSense and Aethair SO₂.

An instrument on Thiamis 2

A third-party instrument connected to a Thiamis gateway, reporting into the same Environet account.

### Placing SO₂ sensors

Because SO₂ is source-concentrated, siting is about capturing the impact of specific emitters: fence-line and downwind positions around power plants, refineries, smelters, and ports, at breathing height with an unobstructed intake and wind speed and direction alongside. For ambient network monitoring, standard urban and industrial-area siting gives representative concentrations. Proximity and wind relative to the source strongly shape the reading, so consistent placement matters for trends and attribution.

### Every device and option that measures Sulfur Dioxide (SO₂) 4

| Device / option | Type | Base platform | Measures |
| - | - | - | - |
| **Aethair MultiSense** `0d09` | MultiSense cartridge | Aethair PRO | Sulfur Dioxide (SO₂) [Formaldehyde (CH₂O)](https://aethair.io/parameters/ch2o/) [Nitrogen Dioxide (NO₂)](https://aethair.io/parameters/no2/) [Dew Point](https://aethair.io/parameters/dew_point/) [Heat Index](https://aethair.io/parameters/heat_index/) [Relative Humidity](https://aethair.io/parameters/humidity/) [Illuminance / Light](https://aethair.io/parameters/light/) |
| **Aethair SO₂** `0d55` | Gas sensor cartridge | Aethair PRO | Sulfur Dioxide (SO₂) [Dew Point](https://aethair.io/parameters/dew_point/) [Heat Index](https://aethair.io/parameters/heat_index/) [Relative Humidity](https://aethair.io/parameters/humidity/) [Illuminance / Light](https://aethair.io/parameters/light/) [Particle Count (by size)](https://aethair.io/parameters/particle_count/) [PM1](https://aethair.io/parameters/pm1/) |
| [RAE](https://aethair.io/sensors/rae-gas-detectors/) · MultiRAE Lite, MultiRAE, MultiRAE Pro… | Gas Detectors | Thiamis | Sulfur Dioxide (SO₂) [Methane (CH₄)](https://aethair.io/parameters/ch4/) [Chlorine (Cl₂)](https://aethair.io/parameters/cl2/) [Carbon Monoxide (CO)](https://aethair.io/parameters/co/) [Carbon Dioxide (CO₂)](https://aethair.io/parameters/co2/) [Hydrogen Sulfide (H₂S)](https://aethair.io/parameters/h2s/) [Combustible (LEL)](https://aethair.io/parameters/lel/) |
| [Trolex](https://aethair.io/sensors/trolex-gas-detectors/) · Sentro X (TX6310) | Gas Detectors | Thiamis | Sulfur Dioxide (SO₂) [Methane (CH₄)](https://aethair.io/parameters/ch4/) [Carbon Monoxide (CO)](https://aethair.io/parameters/co/) [Carbon Dioxide (CO₂)](https://aethair.io/parameters/co2/) [Hydrogen (H₂)](https://aethair.io/parameters/h2/) [Hydrogen Sulfide (H₂S)](https://aethair.io/parameters/h2s/) [Ammonia (NH₃)](https://aethair.io/parameters/nh3/) |

[Configure Sulfur Dioxide (SO₂) Monitoring](https://aethair.io/build/?params=so2)

Where it is monitored

## Solutions That Monitor Sulfur Dioxide (SO₂)

Each one links to the solution page showing what that industry measures it for.

### [Outdoor Monitoring](https://aethair.io/solutions/outdoor-monitoring/#measure-so2)

Core parameter Sulfur dioxide monitoring in ambient air targets the combustion of sulfur-bearing fuels (power generation, shipping, heavy industry, and refining) and the acid deposition and respiratory harm that SO₂ causes.

### [Landfill, Biogas & Odor](https://aethair.io/solutions/landfill-biogas/)

Often added Methane, H₂S, and odor complaint response

### [Occupational Safety & Industrial Hygiene](https://aethair.io/solutions/occupational-safety/)

Often added Worker exposure, confined space, and heat stress

### [Oil & Gas / Petrochemical](https://aethair.io/solutions/oil-gas/)

Often added Fence-line VOC, H₂S, and methane leak detection

Article Library

## Reading on Sulfur Dioxide (SO₂)

### [OSHA Air Quality Standards 2026: PELs & 29 CFR 1910.1000](https://aethair.io/resources/osha-air-quality-standards-compliance/)

OSHA air quality standards for indoor and outdoor work: permissible exposure limits, Table Z-1, 29 CFR 1910.1000, and the heat and wildfire smoke triggers.

### [Ambient Air Quality Monitoring: What Nonattainment Changes](https://aethair.io/resources/ambient-air-quality-monitoring/)

Ambient air quality monitoring explained: how PM2.5 attainment is measured, what a nonattainment designation triggers, and what site-level monitoring adds.

### [Fenceline Air Quality Monitoring: Equipment and Approaches](https://aethair.io/resources/fenceline-air-quality-monitoring/)

Compare fenceline air quality monitoring approaches: standalone stations, pelican-case kits, and connected 4G sensor networks.

### [Data Center Air Quality Monitoring, Inside and Out](https://aethair.io/resources/data-center-air-quality-monitoring/)

Data center air quality monitoring for operators: ISO 14644 cleanliness in the white space, construction dust, generator emissions, and perimeter noise.

### [Types of Air Quality Monitors: Indoor, Outdoor, and Combined](https://aethair.io/resources/types-of-air-quality-monitors/)

Learn the three types of air quality monitors (indoor, outdoor, and combined), what each one measures, and when to use each one.

### [How to Generate Air Quality & Compliance Reports](https://aethair.io/resources/how-to-generate-air-quality-compliance-reports/)

Learn how to generate air quality and environmental compliance reports from monitoring data, plus how automated and AI air quality reporting work.

[All articles](https://aethair.io/resources/)

Related

## More in Gases & VOCs

[Carbon Dioxide (CO₂)](https://aethair.io/parameters/co2/) [VOC (Total)](https://aethair.io/parameters/voc/) [Hydrogen Sulfide (H₂S)](https://aethair.io/parameters/h2s/) [Carbon Monoxide (CO)](https://aethair.io/parameters/co/) [Methane (CH₄)](https://aethair.io/parameters/ch4/) [Oxygen (O₂)](https://aethair.io/parameters/o2/) [Nitric Oxide (NO)](https://aethair.io/parameters/no/) [Nitrogen Dioxide (NO₂)](https://aethair.io/parameters/no2/) [Ammonia (NH₃)](https://aethair.io/parameters/nh3/) [Combustible (LEL)](https://aethair.io/parameters/lel/) [Chlorine (Cl₂)](https://aethair.io/parameters/cl2/) [BTEX / speciated VOC](https://aethair.io/parameters/btex/)

Questions

## Sulfur Dioxide (SO₂) FAQ

Where does sulfur dioxide come from?

Mainly from burning sulfur-containing fuels: coal and oil in power generation and industry, metal smelting, oil refining, and ships burning high-sulfur marine fuel. Because these sources are concentrated, SO₂ monitoring is especially relevant near power plants, refineries, smelters, and ports.

How is SO₂ linked to particulate matter and acid rain?

In the atmosphere, SO₂ oxidizes into sulfate particles, contributing to secondary fine particulate matter, and it forms sulfuric acid that falls as acid rain, damaging soils, waters, and buildings. So controlling SO₂ yields benefits beyond the gas itself, across both PM2.5 and ecosystem health.

What are the limits for SO₂?

Frameworks set different averaging periods: the US EPA NAAQS uses a 1-hour standard, the WHO 2021 guideline sets short-term values, and the EU 2024 directive adds an annual limit for 2030. Occupational limits also apply for workplace exposure. The limit table on this page lists the applicable values with their averaging periods.

How do I monitor sulfur dioxide?

Aethair PRO measures SO₂ with a gas sensor cartridge, or Thiamis can connect an electrochemical multi-gas monitor or a dedicated SO₂ analyzer, with wind data for source attribution near industry and ports. Regulatory networks use UV-fluorescence reference methods. Use the configurator to combine SO₂ with the other criteria pollutants for an ambient or industrial-boundary station.