title: "Aethair IAQ: Commercial Indoor Air Quality Monitor"
description: "Aethair IAQ is a commercial indoor air quality monitor for offices and workplaces, streaming PM1/PM2.5/PM10, CO₂, VOC, and formaldehyde data in real time."
url: https://aethair.io/products/iaq/
---

Aethair monitors

# Aethair IAQ

Commercial Indoor Air Quality Monitor for Offices, Workplaces, and Occupied Buildings

Aethair IAQ measures nine [indoor air quality parameters](https://aethair.io/solutions/iaq-monitoring/#measure): PM1, PM2.5, PM10, total VOC (tVOC), formaldehyde, CO₂, temperature, humidity, and barometric pressure. It also reports raw particle counts by size, total PM from the particle counter, dew point, and heat index, for 13 parameters in all. Every device is calibrated and checked before it ships, with its own Performance Certificate. Readings stream in real time over built-in 4G LTE, with cellular data included. Your team gets an alert when a room drifts out of range, occupants can see air quality on a lobby screen or by QR code, and Aethair Reports documents performance against WELL v2 or Aethair Blue. See the [commercial air quality monitoring solution](https://aethair.io/solutions/iaq-monitoring/) for offices and buildings.

13 built-in parameters

4G LTE built-in, data included

[Schedule an Aethair IAQ Demo](https://calendly.com/d/ctdd-mkr-v9v/aethair-demo-website) [See its built-in sensors](https://aethair.io/sensors/#emb-iaq)

![Aethair IAQ indoor air quality monitor on an office wall](https://aethair.io/images/products/products_preview_iaq.webp)

Aethair IAQ, the commercial indoor monitor

Documents

- [Technical Specifications PDF](https://aethair.io/pdfs/AethairIAQ_SpecSheet.pdf)
- [Product Brochure PDF](https://aethair.io/pdfs/AethairIAQ_Brochure.pdf)

Where it is used

## Where Aethair IAQ Runs

The same monitor, in the buildings that need it. Each tile opens its solution page.

[![Billy Penn Studios atrium viewed from the second-floor balcony.](https://aethair.io/images/products/iaq/billy-penn-studios-atrium.webp)](https://aethair.io/solutions/iaq-monitoring/)

### [Offices and Commercial Buildings](https://aethair.io/solutions/iaq-monitoring/)

[Billy Penn Studios runs Aethair IAQ across 180,000 sq ft of adaptive-reuse tenant space in Philadelphia, with results on public dashboards for tenants and the community.](https://aethair.io/solutions/iaq-monitoring/)

[![Aethair IAQ on a school hallway wall beside the lockers, a QR code sign above it.](https://aethair.io/images/products/iaq/aethair-iaq-school-lockers.webp)](https://aethair.io/solutions/education/)

### [Schools and Education](https://aethair.io/solutions/education/)

[Classroom and library air quality, with the Aethair Air Quality Index on display for staff and students.](https://aethair.io/solutions/education/)

[![Aethair IAQ mounted next to a room number with doctors talking in the background.](https://aethair.io/images/products/iaq/aethair-iaq-4g-wall.webp)](https://aethair.io/solutions/healthcare/)

### [Healthcare](https://aethair.io/solutions/healthcare/)

[Monitor patient and clinical areas without a pressure requirement, with continuous, time-stamped records. A monthly Aethair CMS-2567 report checks humidity, temperature, and air quality against ASHRAE 170 for the surveyor.](https://aethair.io/solutions/healthcare/)

What you get from it

## What You Get From Aethair IAQ

Every reading goes to the Aethair Cloud and appears in Environet. Each outcome below is a product you can read about.

### [Live data and alerts](https://aethair.io/platform/environet/)

[Environet](https://aethair.io/platform/environet/) shows every device live and alerts the people you choose by email, SMS, and webhook, on a reading or its average over any window from 5 minutes to 30 days. [Noesis](https://aethair.io/platform/noesis/) fills in a dashboard, a report, or an alert from a plain-text request.

### [Compliance reports](https://aethair.io/platform/reports/)

[Aethair Reports](https://aethair.io/platform/reports/) writes scheduled or on-demand reports, as PDF or secure link, from templates for Aethair Blue, WELL v2, cabin air (ISO 23875), and the CMS-2567 healthcare codebook (ASHRAE 170), or against your own limits, each on the average you define. [See a sample report](https://aethair.io/docs/aethair-office-air-quality-report-example.pdf).

### [Dashboards and the app](https://aethair.io/platform/dashboards/)

[Aethair Dashboards](https://aethair.io/platform/dashboards/) put live readings on screens, online or by QR code, and the [Aethair App](https://aethair.io/platform/app/) puts them on phones. Dashboards can be shared publicly: [Billy Penn Studios](https://aethair.io/solutions/billypennstudios/) publishes its readings to tenants and the community. [See a live dashboard example](https://dashboard.environet.io/?token=7e8ea79a-8dfd-4412-bafe-e7506037d12d).

### Your data, stored until delivered

Aethair IAQ caches readings on the device until they are delivered, so a connectivity outage delays readings instead of dropping them, and raw readings are stored exactly as the device sent them. Every reading is encrypted in transit to the Aethair Cloud and platform access is role-based. Live and historical readings export as JSON or CSV through the [Environet API](https://docs.environet.io/) (OpenAPI 3.2). You own your devices and data, can grant partners controlled access, and readings are kept for as long as you need them (at least two years after a project ends) and deleted only at your request.

### Calibrated, with a certificate

Each Aethair IAQ ships with a Performance Certificate for its serial number. On the [example certificate](https://aethair.io/docs/1C002887.pdf), CO₂, temperature, humidity, and total VOC are checked against reference devices (a Fluke 1620A for temperature and humidity, a ppbRAE 3000 for total VOC, a reference unit for CO₂), with the correlation (R 0.99 and above, R² beside it) and the p75, p90, and p95 errors. The PM2.5 and formaldehyde sensors are calibrated at the factory by their maker, Plantower, and checked by Aethair. Calibration uses NIST-traceable reference standards.

### One account for every site

Every Aethair IAQ, at every site, sits in the same Environet account as Aethair PRO and Thiamis-connected sensors: one console, the same alerts, reports, and dashboards for every device.

What it measures

## Built-In Sensors

| Parameter | Range | Resolution | What it measures |
| - | - | - | - |
| [PM1 µg/m³](https://aethair.io/parameters/pm1/) | 0–500 µg/m³ | 1 µg/m³ | Submicron particulate ≤1 µm, the fraction that penetrates deepest into the lungs. Measured by 90° laser light-scattering, in µg/m³. |
| [PM2.5 µg/m³](https://aethair.io/parameters/pm2_5/) | 0–500 µg/m³ | 1 µg/m³ | Fine particulate ≤2.5 µm, the headline health metric behind [NAAQS](https://aethair.io/standards/epa_naaqs/) and WHO limits. 90° laser light-scattering, µg/m³. |
| [PM10 µg/m³](https://aethair.io/parameters/pm10/) | 0–500 µg/m³ | 1 µg/m³ | Coarse particulate ≤10 µm: dust, pollen, and road grit. Measured by 90° laser light-scattering, in µg/m³. |
| [Total PM / Mass Conc. µg/m³](https://aethair.io/parameters/pm_total/) | — | — | Peak PM within the one-minute reporting window: the highest PM10 value the counter saw in that minute, µg/m³. |
| [Particle Count (by size) particles ≥0.3 µm, ≥0.5 µm, ≥1.0 µm, ≥2.5 µm, ≥5.0 µm, ≥10.0 µm](https://aethair.io/parameters/particle_count/) | — | — | Raw particle counts in six optical size bins (≥0.3, ≥0.5, ≥1.0, ≥2.5, ≥5.0, and ≥10.0 µm) from the laser counter, used to derive the PM mass fractions. |
| [Carbon Dioxide (CO₂) ppm](https://aethair.io/parameters/co2/) | 400–5000 ppm | 1 ppm | Carbon dioxide by NDIR (non-dispersive infrared), the standard proxy for ventilation adequacy in occupied spaces. ppm. |
| [VOC (Total) ppm](https://aethair.io/parameters/voc/) | 0–1 ppm | 0.05 ppm | Total volatile organic compounds, isobutylene-referenced (also reported on an ethanol scale), as an indicator of chemical load and freshness. ppm. |
| [Air Temperature °C / °F](https://aethair.io/parameters/temperature/) | 0–45 °C | 0.1 °C | Air temperature, reported in °C or °F. |
| [Relative Humidity %](https://aethair.io/parameters/humidity/) | 15–75 % | 0.1 % | Relative humidity, %. |
| [Barometric Pressure hPa](https://aethair.io/parameters/pressure/) | 300–1100 hPa | — | Barometric pressure, hPa. |
| [Dew Point °C / °F](https://aethair.io/parameters/dew_point/) | — | — | Dew point (the temperature at which air becomes saturated), derived from temperature and humidity. °C or °F. |
| [Heat Index °C / °F](https://aethair.io/parameters/heat_index/) | — | — | Heat index (apparent temperature), derived from temperature and humidity. °C or °F. |
| [Formaldehyde (CH₂O) mg/m³](https://aethair.io/parameters/ch2o/) | 0–1 mg/m³ | 0.001 mg/m³ | Formaldehyde, a hallmark indoor pollutant off-gassed by building materials, furnishings, and finishes. mg/m³. |

How it is built

## Aethair IAQ Hardware

Sensor ranges and resolutions are in the table above. All other Aethair IAQ specifications are listed below.

### General

| Input voltage | 5 VDC (micro-USB) |
| - | - |
| Power | 0.6 W |
| Operating temperature | 0–45 °C |
| Accelerometer | 16 g, 13-bit resolution |
| Dimensions (L×W×D) | 4.3 in (110 mm) × 2.6 in (66 mm) × 1.2 in (30 mm) |
| Weight | 0.4 lb (0.18 kg) |
| Certifications | CE, FCC |
| Particle sensor | Laser light scattering; counts reported in six cumulative bins from 0.3 µm, PM as mass ≤1, ≤2.5, and ≤10 µm (sheet size channels 0.3–1.0, 1.0–2.5, 2.5–10 µm); counting efficiency 98 % at ≥ 0.5 µm |
| Reporting | Sensors sampled every 2–5 s; a one-minute average (median for CO₂ and VOC) published every minute |
| Updates | Firmware and configuration over the air, from Environet |

### Communications

| Cellular | 4G LTE / 3G / 2G |
| - | - |
| WiFi | 802.11 b/g |
| Bluetooth | Bluetooth 4.0 |
| Mesh | Zigbee |
| GPS | A-GPS |
| Antenna | Built-in (GPRS, 2G/3G/4G, Zigbee, Bluetooth) |
| SIM card | Built-in; cellular data included, no network fee |

Source: [Aethair IAQ Technical Specifications](https://aethair.io/pdfs/AethairIAQ_SpecSheet.pdf) (2nd generation, Rev. 1.0, August 2024).

Still deciding?

## The Other Aethair Devices: Aethair PRO and Thiamis

### [Aethair PRO](https://aethair.io/products/pro/)

[Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.](https://aethair.io/products/pro/)

[13 built-in parameters (PM2.5, PM10, noise, temperature …), plus 19 swappable cartridges (H₂S, SO₂, NO₂, CO, O₃, CH₄ and more) in 2 gas sockets, 1 MultiSense socket, and 1 expansion socket](https://aethair.io/products/pro/)

[See Aethair PRO](https://aethair.io/products/pro/)

### [Thiamis](https://aethair.io/products/thiamis/)

[A gateway that connects the third-party instruments you choose to the Aethair Platform.](https://aethair.io/products/thiamis/)

[RS-232, RS-485, SDI-12, and USB · 224 device models from 35 integrations](https://aethair.io/products/thiamis/)

[See Thiamis](https://aethair.io/products/thiamis/)

Standards

## Monitor for These Standards with Aethair IAQ

[WHO Global Air Quality Guidelines 2021](https://aethair.io/standards/who_aqg_2021/) [WELL Building Standard v2: Air](https://aethair.io/resources/well-building-standard-air-quality/) [LEED v5: Indoor Air Quality Performance (Operations and Maintenance)](https://aethair.io/standards/leed_v5/) [RESET Air: commercial interiors performance targets](https://aethair.io/standards/reset_air/) [USP General Chapter <797>: pharmaceutical compounding, sterile preparations](https://aethair.io/standards/usp_797/) [ISO 14644-1: cleanroom classification by particle concentration](https://aethair.io/standards/iso_14644_1/) [ASHRAE TC 9.9: data center contamination and environmental guidelines](https://aethair.io/standards/ashrae_tc99/) [OSHA Permissible Exposure Limits (PEL)](https://aethair.io/resources/osha-air-quality-standards-compliance/) [ACGIH Threshold Limit Values (TLV)](https://aethair.io/standards/acgih_tlv/) [Indoor CO₂ Guideline (German UBA / Pettenkofer scale)](https://aethair.io/standards/uba_indoor_co2/) [NIOSH Recommended Exposure Limits (RELs)](https://aethair.io/standards/niosh_rel/) [OSHA Construction Exposure Limits (29 CFR 1926.55)](https://aethair.io/standards/osha_construction_pel/) [Cal/OSHA Permissible Exposure Limits (8 CCR §5155, Table AC-1)](https://aethair.io/standards/cal_osha_pel/) [ISO 23875: air quality control systems for operator enclosures](https://aethair.io/standards/iso_23875/) [ANSI/ASHRAE/ASHE Standard 170: ventilation of health care facilities](https://aethair.io/resources/ashrae-170-requirements/) [USP General Chapter <800>: hazardous drugs, handling in healthcare settings](https://aethair.io/standards/usp_800/) [WHO Indoor Air Quality Guidelines (2010): formaldehyde](https://aethair.io/standards/who_iaq_2010/) [OSHA Formaldehyde Standard (29 CFR 1910.1048)](https://aethair.io/standards/osha_formaldehyde/)

Guidance that references these measurements without setting a limit:

[ANSI/ASHRAE Standard 62.1: ventilation for acceptable indoor air quality](https://aethair.io/standards/ashrae_62_1/)

Article Library

## Reading for Aethair IAQ Deployments

Guides to the indoor programs and standards Aethair IAQ is used for.

### [Aethair IAQ vs Kaiterra Sensedge Mini: IAQ Monitors Compared](https://aethair.io/resources/aethair-iaq-vs-kaiterra-sensedge-mini/)

Aethair IAQ vs Kaiterra Sensedge Mini compared on connectivity, sensors, accuracy, and platform, and how to choose the right commercial IAQ monitor.

### [How Building Certifications Use Air Quality Monitoring](https://aethair.io/resources/building-certifications-air-quality-monitoring/)

How WELL and LEED v5 incorporate air quality monitoring, why both frameworks are moving toward continuous performance, and what that means for building teams.

### [Workplace Air Quality Monitoring for Offices and Employers](https://aethair.io/resources/workplace-air-quality-monitoring/)

How to monitor workplace air quality in offices, what to measure for employee health and focus, and how continuous connected monitoring documents the result.

### [Indoor Air Quality in Schools: Standards & Monitoring 2026](https://aethair.io/resources/indoor-air-quality-schools/)

Indoor air quality in schools: which standards apply, what to monitor, and how CO2 and ventilation affect student attendance, health, and test scores.

### [Commercial Building IAQ Monitoring: ASHRAE 62.1 & WELL](https://aethair.io/resources/indoor-air-quality-monitoring-commercial-buildings/)

Indoor air quality monitoring for commercial buildings: what to measure, which standards apply, and how property managers build a program tenants trust.

### [PM2.5 Exposure Limits & Monitoring: OSHA and NAAQS Standards](https://aethair.io/resources/pm25-monitoring-health-regulatory-guide/)

What are the OSHA and NAAQS exposure limits for PM2.5? Fine particulate thresholds explained, plus how continuous monitoring keeps workplaces compliant.

[All articles](https://aethair.io/resources/)

Questions

## Aethair IAQ FAQ

How is Aethair IAQ different from a consumer air quality monitor?

It is built for professional use. Every unit is calibrated against NIST-traceable reference standards and ships with a certificate showing, sensor by sensor, how it compares with a reference device or who calibrated it. Every report traces back to time-stamped readings, stored exactly as the device sent them. It is still a sensor-based monitor, not a reference method. One account manages a whole portfolio of devices rather than a single room, and the data flows through the [Environet API](https://docs.environet.io/) into your own systems.

How does Aethair IAQ support EHS and compliance programs?

Set thresholds at the indoor limits your program uses: WELL v2's formaldehyde, total VOC, and PM2.5 thresholds, CO₂ at WELL's 900 ppm ventilation-monitoring level (or 750 ppm for its enhanced-ventilation points), Aethair Blue, or your own targets, each on the averaging period it is defined over. Occupational exposure limits such as OSHA PELs are set per compound, far above typical office concentrations, and are measured by personal sampling over a shift, so an IAQ program doesn't check against them. Alerts, reports, and exports then work as described under What You Get.

Can Aethair IAQ feed our building management system?

Yes, through the [Environet API](https://docs.environet.io/) and webhooks. Your BMS integration can read live and historical readings as JSON or CSV through the API, or receive each reading as it arrives through a webhook, for example to drive demand-controlled ventilation from CO₂.

How do I install Aethair IAQ in my building?

Mount each unit indoors near a power outlet for its 5 VDC micro-USB supply, and plug it in to power it on. It reports over built-in 4G LTE with its own SIM, so it needs no site network or Wi-Fi onboarding. Where cellular coverage is weak, it can join the site's Wi-Fi instead. Readings are cached on the device during a network outage. Your own staff can install it, with no special license needed, or a partner from Aethair's network can do it for you.

How is Aethair IAQ bought?

The hardware is a one-time purchase: the monitors and their accessories. The platform is an annual subscription, on a one- to three-year contract, that covers every platform feature. Cellular data and data hosting are included, with no network fee. Buying starts with a 30-minute call: you tell us about your application, then we demo the solution for it.