title: "Parker icountPD Fluid & Fuel Quality | Aethair"
description: "Parker icountPD inline laser particle detector in the Aethair sensor catalog: ISO 4406 codes for hydraulic, lube-oil, and fuel systems via Thiamis."
url: https://aethair.io/sensors/parker-fluid-fuel-quality/
---

Sensors · Fluid & Fuel Quality

# Parker icountPD

Fluid & Fuel Quality

Parker icountPD inline/online laser particle detector for hydraulic, lube-oil, and fuel systems; laser-diode optical particle counting reports fluid cleanliness as ISO 4406 codes (also NAS 1638 / AS4059) across four size channels >4/>6/>14/>30 µm(c), to ±1 ISO code, over RS-232.

[Schedule a call](https://calendly.com/d/ctdd-mkr-v9v/aethair-demo-website) [Build a Configuration](https://aethair.io/build/?params=particle_count_fluid)

At a glance

**1** parameter **1** model

[**Connects via Thiamis** RS-232 · ASCII](https://aethair.io/products/thiamis/)

Measures

## What the Parker icountPD Measures

1 parameter, linked to its page on sensors, units, and standards.

[Fluid Particle Count (ISO 4406) ISO 4406 code >4 µm(c), >6 µm(c), >14 µm(c), >30 µm(c)](https://aethair.io/parameters/particle_count_fluid/)

[Connects via **Thiamis**](https://aethair.io/products/thiamis/)

Wired interface [RS-232 ASCII](https://aethair.io/products/thiamis/#port-rs232)

Models

## Parker icountPD Models

1 model, with what it measures and the ranges from its datasheet.

| Model | Description | Measures & specs |
| - | - | - |
| **icountPD** | Permanently mounted online laser-diode particle detector for hydraulic and lube/fuel circuits. It reports ISO 4406 (and NAS 1638 / AS4059) cleanliness codes at >4/>6/>14/>30 µm(c) to ±1 ISO code. RS-232 serial plus 4–20 mA, 0–5 V, and CAN-bus (J1939) outputs; inline or remote-mount, with an optional moisture/temperature sensor on non-fuel versions. | [Fluid Particle Count (ISO 4406) >4 µm(c), >6 µm(c), >14 µm(c), >30 µm(c)](https://aethair.io/parameters/particle_count_fluid/) |

Standards

## Standards for What It Measures

Standards that set limits on the parameters it reports, plus any method standard the instrument is built to.

Built to [ISO 4406: fluid cleanliness coding (SAE AS4059; NAS 1638 legacy)](https://aethair.io/standards/iso_4406/) [ISO 11171: calibration of automatic particle counters for liquids](https://aethair.io/standards/iso_11171/)

Solutions

## Where the Parker icountPD Is Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

### [Hydraulic & Fuel Cleanliness](https://aethair.io/solutions/industrial-fluids/)

ISO 4406 oil cleanliness and aviation fuel

On the platform

## What the Parker icountPD Gets From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

### [Live data and alerts](https://aethair.io/platform/environet/)

[Environet](https://aethair.io/platform/environet/) shows the instrument live and alerts the people you choose by email, SMS, and webhook, at the thresholds you set. [Noesis](https://aethair.io/platform/noesis/) sets up a dashboard, a report, or an alert from a plain-text request.

### [Compliance reports](https://aethair.io/platform/reports/)

[Aethair Reports](https://aethair.io/platform/reports/) produces scheduled or on-demand reports from the instrument's readings, as a PDF or secure link. Templates cover Aethair Blue, WELL v2, cabin air (ISO 23875), and the CMS-2567 healthcare codebook (ASHRAE 170), or you can report against custom limits such as OSHA PELs, NAAQS, EPA guidance, or your own program limits.

### [Dashboards and the app](https://aethair.io/platform/dashboards/)

Environet dashboards and the [Aethair App](https://aethair.io/platform/app/) show the instrument's readings just like any Aethair device. The occupant-facing [Aethair Dashboards](https://aethair.io/platform/dashboards/) status display is built around Aethair IAQ and Aethair PRO.

Similar

## Other Fluid & Fuel Quality

### [Parker Velcon](https://aethair.io/sensors/parker-velcon-fluid-fuel-quality/)

[Fluid & Fuel Quality](https://aethair.io/sensors/parker-velcon-fluid-fuel-quality/)

[The Parker Velcon FDPM (Flow Differential Pressure Module) is used on aviation-fuel filter vessels.…](https://aethair.io/sensors/parker-velcon-fluid-fuel-quality/)

Questions

## Parker icountPD FAQ

How does the Parker icountPD report fluid cleanliness?

It uses laser-diode optical detection of the particles in a live oil or fuel sample and expresses the result as ISO 4406 cleanliness codes, one code per size channel at >4, >6, >14, and >30 µm(c), with a stated performance of ±1 ISO code. The same measurement can also be reported as NAS 1638 or AS4059 classes.

What do the four size channels mean?

Each channel is a cumulative particle-size threshold calibrated to ISO 11171 (the '(c)' suffix): >4 µm(c), >6 µm(c), >14 µm(c), and >30 µm(c). The >4/>6/>14 codes are the standard three-part ISO 4406 code shown on the front display; the fourth channel, >30 µm(c), is a coarse-particle code Parker adds for fuel/aviation cleanliness and carries on the serial and CAN outputs. Thiamis reads all four; mineral-oil units report only the three standard channels.

How does Thiamis connect to the icountPD?

Over the icountPD's RS-232 serial output, reporting in ISO 4406. The icountPD also provides 4–20 mA, 0–5 V, and CAN-bus (J1939) outputs, but the Thiamis integration uses the RS-232 connection.

Does the icountPD measure water or moisture content?

Non-fuel versions can be fitted with an optional moisture (%RH) and temperature sensor, but the Thiamis integration ingests only the ISO 4406 particle-cleanliness codes, not moisture or temperature.

Which fluids and operating conditions does it suit?

Mineral and hydraulic oils, phosphate-ester (fire-resistant) fluids, and aviation/petroleum fuels, at 2–420 bar and fluid viscosity of 1–500 cSt, with a measurement cycle of roughly 30 seconds.

Sources: [ph.parker.com](https://ph.parker.com/us/en/product-list/icountpd-online-particle-detector) · [www.parker.com](https://www.parker.com/content/dam/Parker-com/Literature/Hydraulic-Filter-Division-Europe/Websphere-Literature/BROCHURE-icountPD-Particle-Detector.pdf)