title: "TSI DustTrak Particulate & Dust Monitors | Aethair"
description: "TSI DustTrak II and DRX laser photometers in the Aethair sensor catalog: 11 models for real-time PM1 to PM10 and total dust, connected through Thiamis."
url: https://aethair.io/sensors/tsi-particulate-dust-monitors/
---

Sensors · Particulate & Dust Monitors

# TSI DustTrak

Particulate & Dust Monitors

TSI DustTrak real-time light-scattering laser photometers for aerosol/dust mass-concentration monitoring. DustTrak II reports one user-selected size fraction; DustTrak DRX reports PM1/PM2.5/PM4/PM10/Total simultaneously; Environmental models (8540/8543) add a weatherproof enclosure for outdoor/fence-line use, and the M variants add MCERTS certification.

[Schedule a call](https://calendly.com/d/ctdd-mkr-v9v/aethair-demo-website) [Build a Configuration](https://aethair.io/build/?params=pm1,pm2_5,pm4,pm10,pm_total)

At a glance

**5** parameters **11** models

[**Connects via Thiamis** RS-232 · ASCII](https://aethair.io/products/thiamis/)

4 standards limit what it measures

- [EU 2024/2881 EU Ambient Air Quality Directive (EU) 2024/2881](https://aethair.io/standards/eu_aaqd_2024/)
- [LEED v5 LEED v5: Indoor Air Quality Performance (Operations and Maintenance)](https://aethair.io/standards/leed_v5/)
- [SCAQMD 1180 SCAQMD Rule 1180: refinery fenceline and community air monitoring](https://aethair.io/standards/scaqmd_1180/)
- [EPA NAAQS US EPA National Ambient Air Quality Standards (NAAQS)](https://aethair.io/standards/epa_naaqs/)

Measures

## What the TSI DustTrak Measures

5 parameters, each linked to its page: the sensors, units, and standards behind it.

[PM1 mg/m³ / µg/m³](https://aethair.io/parameters/pm1/) [PM2.5 mg/m³ / µg/m³](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable) mg/m³ / µg/m³](https://aethair.io/parameters/pm4/) [PM10 mg/m³ / µg/m³](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc. mg/m³ / µg/m³](https://aethair.io/parameters/pm_total/)

[Connects via **Thiamis**](https://aethair.io/products/thiamis/)

Wired interface [RS-232 ASCII](https://aethair.io/products/thiamis/#port-rs232)

Models

## TSI DustTrak Models

11 models, each with what it measures and the ranges its datasheet gives.

| Model | Description | Measures & specs |
| - | - | - |
| **DustTrak 8530** | DustTrak II desktop laser photometer with internal pump; one user-selected size fraction (PM1/PM2.5/Respirable/PM10) reported as mass concentration. | **Range:** 0.001–400 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8530EP** | DustTrak II desktop with low-power external pump for continuous 24/7 unattended outdoor monitoring; one user-selected size fraction. | **Range:** 0.001–400 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8532** | DustTrak II handheld laser photometer for walk-through surveys; one user-selected size fraction, real time. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8540** | DustTrak Environmental single-fraction monitor in a weatherproof enclosure for outdoor/fence-line use. | **Range:** 0.001–400 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8533** | DustTrak DRX desktop; PM1/PM2.5/PM4/PM10/Total simultaneously from one sample. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading) **Method:** Light-scattering laser photometer (with gravimetric reference sampling) [datasheet](https://tsi.com/getmedia/971b8eee-a3da-44be-972f-3aab3ef138b1/DustTrak-DRX-6001981_USA-web?ext=.pdf)[PM1](https://aethair.io/parameters/pm1/) [PM2.5](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable)](https://aethair.io/parameters/pm4/) [PM10](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8533EP** | DustTrak DRX desktop with external pump for extended long-term sampling; simultaneous PM1-Total. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading) **Method:** Light-scattering laser photometer (with gravimetric reference sampling) [datasheet](https://tsi.com/getmedia/971b8eee-a3da-44be-972f-3aab3ef138b1/DustTrak-DRX-6001981_USA-web?ext=.pdf)[PM1](https://aethair.io/parameters/pm1/) [PM2.5](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable)](https://aethair.io/parameters/pm4/) [PM10](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8534** | DustTrak DRX handheld; simultaneous PM1/PM2.5/PM4/PM10/Total. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading) **Method:** Light-scattering laser photometer (with gravimetric reference sampling) [datasheet](https://tsi.com/getmedia/971b8eee-a3da-44be-972f-3aab3ef138b1/DustTrak-DRX-6001981_USA-web?ext=.pdf)[PM1](https://aethair.io/parameters/pm1/) [PM2.5](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable)](https://aethair.io/parameters/pm4/) [PM10](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8543** | DustTrak Environmental DRX; simultaneous PM1-Total in a weatherproof enclosure. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[PM1](https://aethair.io/parameters/pm1/) [PM2.5](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable)](https://aethair.io/parameters/pm4/) [PM10](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |
| **DustTrak 8540M** | DustTrak Environmental single-fraction, MCERTS-certified for PM2.5; weatherproof enclosure with built-in auto-zero. | **Range:** 0.001–400 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[PM2.5](https://aethair.io/parameters/pm2_5/) |
| **DustTrak 8542M** | DustTrak Environmental single-fraction, MCERTS-certified for PM10; weatherproof enclosure with built-in auto-zero. | **Range:** 0.001–400 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[PM10](https://aethair.io/parameters/pm10/) |
| **DustTrak 8543M** | DustTrak Environmental DRX, MCERTS-certified for both PM2.5 and PM10; simultaneous PM1/PM2.5/PM4/PM10/Total for regulatory monitoring. | **Range:** 0.001–150 mg/m³ **Resolution:** 0.001 mg/m³ (or 0.1% of reading)[PM1](https://aethair.io/parameters/pm1/) [PM2.5](https://aethair.io/parameters/pm2_5/) [PM4 (Respirable)](https://aethair.io/parameters/pm4/) [PM10](https://aethair.io/parameters/pm10/) [Total PM / Mass Conc.](https://aethair.io/parameters/pm_total/) |

Standards

## Standards for What It Measures

Standards that set limits on the parameters it reports.

[EU 2024/2881 EU Ambient Air Quality Directive (EU) 2024/2881 2 of its parameters](https://aethair.io/standards/eu_aaqd_2024/) [LEED v5 LEED v5: Indoor Air Quality Performance (Operations and Maintenance) 2 of its parameters](https://aethair.io/standards/leed_v5/) [SCAQMD 1180 SCAQMD Rule 1180: refinery fenceline and community air monitoring 2 of its parameters](https://aethair.io/standards/scaqmd_1180/) [EPA NAAQS US EPA National Ambient Air Quality Standards (NAAQS) 2 of its parameters](https://aethair.io/standards/epa_naaqs/) [WELL v2 WELL Building Standard v2: Air 2 of its parameters](https://aethair.io/resources/well-building-standard-air-quality/) [WHO 2021 WHO Global Air Quality Guidelines 2021 2 of its parameters](https://aethair.io/standards/who_aqg_2021/) [Cal/OSHA 5141.1 Cal/OSHA Protection from Wildfire Smoke (8 CCR §5141.1) 1 of its parameters](https://aethair.io/standards/cal_osha_5141_1/) [ISO 23875 ISO 23875: air quality control systems for operator enclosures 1 of its parameters](https://aethair.io/standards/iso_23875/) [NYSDEC DER-10 NYSDEC DER-10 Community Air Monitoring Plan (CAMP) 1 of its parameters](https://aethair.io/standards/nysdec_der10/) [RESET Air RESET Air: commercial interiors performance targets 1 of its parameters](https://aethair.io/standards/reset_air/) [SCAQMD 1466 SCAQMD Rule 1466: particulate emissions from soils with toxic air contaminants 1 of its parameters](https://aethair.io/standards/scaqmd_1466/) [EPA AQI US EPA Air Quality Index (AQI): PM2.5 breakpoints (2024) 1 of its parameters](https://aethair.io/standards/epa_aqi/)

Solutions

## Where the TSI DustTrak Is Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

### [Perimeter Monitoring](https://aethair.io/solutions/perimeter-monitoring/)

Site boundary dust, silica, and noise compliance

### [Outdoor Monitoring](https://aethair.io/solutions/outdoor-monitoring/)

Continuous outdoor air quality networks that sit alongside reference monitors

### [Wildfire Air Monitoring](https://aethair.io/solutions/wildfires/)

Smoke plumes, black carbon, and community exposure

### [Cabin Air Quality](https://aethair.io/solutions/cabin-air/)

Respirable dust, gases, and blast monitoring

### [Healthcare Air Monitoring](https://aethair.io/solutions/healthcare/)

Clinical air quality, pressurization, and patient safety

### [Indoor Air Quality](https://aethair.io/solutions/iaq-monitoring/)

Offices, schools, homes, and public buildings

### [School Air Monitoring](https://aethair.io/solutions/education/)

Classroom CO₂, particulates, and campus IAQ

On the platform

## What the TSI DustTrak Gets From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

### [Live data and alerts](https://aethair.io/platform/environet/)

[Environet](https://aethair.io/platform/environet/) shows the instrument live and alerts the people you choose by email, SMS, and webhook, at the thresholds you set. [Noesis](https://aethair.io/platform/noesis/) sets up a dashboard, a report, or an alert from a plain-text request.

### [Compliance reports](https://aethair.io/platform/reports/)

[Aethair Reports](https://aethair.io/platform/reports/) produces scheduled or on-demand reports from the instrument's readings, as a PDF or secure link. Templates cover Aethair Blue, WELL v2, cabin air (ISO 23875), and the CMS-2567 healthcare codebook (ASHRAE 170), or you can report against custom limits such as OSHA PELs, NAAQS, EPA guidance, or your own program limits.

### [Dashboards and the app](https://aethair.io/platform/dashboards/)

Environet dashboards and the [Aethair App](https://aethair.io/platform/app/) show the instrument's readings just like any Aethair device. The occupant-facing [Aethair Dashboards](https://aethair.io/platform/dashboards/) status display is built around Aethair IAQ and Aethair PRO.

Similar

## Other Particulate & Dust Monitors

### [Met One](https://aethair.io/sensors/met-one-particulate-dust-monitors/)

[Particulate & Dust Monitors](https://aethair.io/sensors/met-one-particulate-dust-monitors/)

[Met One (Acoem) real-time particulate monitors. The E-BAM is a portable beta-attenuation mass…](https://aethair.io/sensors/met-one-particulate-dust-monitors/)

### [Particles Plus](https://aethair.io/sensors/particles-plus-particulate-dust-monitors/)

[Particulate & Dust Monitors](https://aethair.io/sensors/particles-plus-particulate-dust-monitors/)

[Particles Plus 5000-series remote (fixed-install) and 7000-series benchtop instruments are laser…](https://aethair.io/sensors/particles-plus-particulate-dust-monitors/)

### [Thermo Scientific](https://aethair.io/sensors/thermo-scientific-particulate-dust-monitors/)

[Particulate & Dust Monitors](https://aethair.io/sensors/thermo-scientific-particulate-dust-monitors/)

[This integration covers Thermo Scientific particulate monitors, led by the Partisol iSeries…](https://aethair.io/sensors/thermo-scientific-particulate-dust-monitors/)

### [Trolex](https://aethair.io/sensors/trolex-particulate-dust-monitors/)

[Particulate & Dust Monitors](https://aethair.io/sensors/trolex-particulate-dust-monitors/)

[Trolex real-time dust and silica monitors for harsh mining and industrial environments: the Air XD…](https://aethair.io/sensors/trolex-particulate-dust-monitors/)

Article Library

## Reading on What These Instruments Measure

### [Fenceline Air Quality Monitoring: Equipment and Approaches](https://aethair.io/resources/fenceline-air-quality-monitoring/)

Compare fenceline air quality monitoring approaches: standalone stations, pelican-case kits, and connected 4G sensor networks.

### [PM2.5 Exposure Limits & Monitoring: OSHA and NAAQS Standards](https://aethair.io/resources/pm25-monitoring-health-regulatory-guide/)

What are the OSHA and NAAQS exposure limits for PM2.5? Fine particulate thresholds explained, plus how continuous monitoring keeps workplaces compliant.

[All articles](https://aethair.io/resources/)

Questions

## TSI DustTrak FAQ

How does the DustTrak measure dust concentration?

It is a light-scattering laser photometer: the aerosol is drawn through a sheath-air optics chamber and the 90-degree light scattered from a laser diode is converted to a real-time mass concentration in mg/m3. A user-inserted 37 mm gravimetric filter cassette lets you collect a reference sample for custom (gravimetric) calibration.

What is the difference between DustTrak II and DustTrak DRX?

DustTrak II (8530, 8530EP, 8532) is single-channel: it reports one user-selected size fraction, set by the inlet impactor (PM1, PM2.5, Respirable/PM4, or PM10), as a single mass concentration. DustTrak DRX (8533, 8533EP, 8534, and the Environmental 8543/8543M) uses a size-segregated technique to report PM1, PM2.5, PM4 (Respirable), PM10, and Total PM simultaneously from one sample.

What do the EP models add?

EP (8530EP, 8533EP) is a desktop unit with a low-power external pump for continuous, unattended 24/7 monitoring over days to months. The standard desktop (8530, 8533) uses an internal pump suited to shorter work-shift or indoor-air-quality sampling.

What do the M models add, and which fraction is each certified for?

The M models are the MCERTS-certified DustTrak Environmental builds for UK/EU regulatory use, in a weatherproof enclosure with built-in auto-zero. 8540M is certified for PM2.5, 8542M for PM10, and 8543M is the DRX build certified for both PM2.5 and PM10.

Does the integration report a Short-Term Exposure Limit (STEL)?

Yes. The driver supports a 15-minute STEL alarm per size fraction (PM1, PM2.5, PM4, PM10, Total); when a per-fraction setpoint is exceeded it posts the 15-minute average. STEL is an alarm value, not a separately measured parameter.

How does the Thiamis integration talk to the instrument?

Over RS-232 serial at 9600 baud, 8-N-1. On connection the driver auto-detects the model and polls the instrument each interval; the model determines whether one mass value (single-fraction) or five (DRX) are ingested.

Sources: [tsi.com](https://tsi.com/products/aerosol-and-dust-monitors/aerosol-and-dust-monitors/dusttrak-ii-aerosol-monitor-8530) · [tsi.com](https://tsi.com/products/aerosol-and-dust-monitors/aerosol-and-dust-monitors/dusttrak-drx-aerosol-monitor-8533) · [tsi.com](https://tsi.com/products/environmental-air-monitors/environmental-monitors/dusttrak-environmental-monitor-8540) · [tsi.com](https://tsi.com/getmedia/8a033c16-e440-4d3a-b286-954f4e6d3043/DustTrak-II-6001986-USA-web?ext=.pdf) · [tsi.com](https://tsi.com/getmedia/971b8eee-a3da-44be-972f-3aab3ef138b1/DustTrak-DRX-6001981_USA-web?ext=.pdf) · [tsi.com](https://tsi.com/getmedia/1b85aeb9-6b3a-4521-b9fa-b8a15ee7dd3d/DustTrak-Environmental_Models-8540-and-8543_A4_5002439_Rev-A_Web?ext=.pdf)