# Cal/OSHA Permissible Exposure Limits (8 CCR §5155, Table AC-1)

Occupational: legal limit (California), 8-hour TWA unless noted

California sets its own workplace exposure limits in **8 CCR §5155, Airborne Contaminants**, whose **Table AC-1** lists a permissible exposure limit (8-hour TWA), a short-term exposure limit (15-minute), and a ceiling for each regulated substance. Cal/OSHA has updated its table far more recently than federal OSHA, so many values are stricter. Examples include **carbon monoxide at 25 ppm with a 200 ppm ceiling** (federal: 50 ppm); **ozone at 0.1 ppm with a 0.3 ppm STEL**; **sulfur dioxide at 2 ppm with a 5 ppm STEL**; **hydrogen sulfide at 10 ppm with a 15 ppm STEL and a 50 ppm ceiling**; and **nitrogen dioxide with a 1 ppm STEL**.

[Schedule a call](https://calendly.com/d/ctdd-mkr-v9v/aethair-demo-website) [Configure Cal/OSHA PEL Monitoring](https://aethair.io/build/?params=co,co2,h2s,so2,no,no2,o3,nh3,cl2,hg,hcl,hf,btex)

At a glance

**Cal/OSHA** Occupational: legal limit (California), 8-hour TWA unless noted

13 parameters · 25 limit values

[Carbon Monoxide (CO)](https://aethair.io/parameters/co/) [Carbon Dioxide (CO₂)](https://aethair.io/parameters/co2/) [Hydrogen Sulfide (H₂S)](https://aethair.io/parameters/h2s/) [Sulfur Dioxide (SO₂)](https://aethair.io/parameters/so2/) [Nitric Oxide (NO)](https://aethair.io/parameters/no/) [Nitrogen Dioxide (NO₂)](https://aethair.io/parameters/no2/) [Ozone (O₃)](https://aethair.io/parameters/o3/) [Ammonia (NH₃)](https://aethair.io/parameters/nh3/) [Chlorine (Cl₂)](https://aethair.io/parameters/cl2/) [Mercury (Hg)](https://aethair.io/parameters/hg/) [Hydrogen Chloride (HCl)](https://aethair.io/parameters/hcl/) [Hydrogen Fluoride (HF)](https://aethair.io/parameters/hf/) [BTEX / speciated VOC](https://aethair.io/parameters/btex/)

2 devices measure them all

- **Aethair PRO** Aethair O₃+NO₂ · Aethair CO (electrochemical) · Custom MultiSense
- **Thiamis** RAE Gas Detectors · Defiant Technologies Specialty Air Analyzers · AMETEK Brookfield Specialty Air Analyzers

[Official text from Cal/OSHA](https://www.dir.ca.gov/title8/5155.html)

Limit values

## Cal/OSHA PEL Limit Values

Every value Cal/OSHA publishes for the 13 parameters below, with its averaging period, as the standard states it.

[**Carbon Monoxide (CO)** Gases & VOCs](https://aethair.io/parameters/co/)

**25 ppm** *8-hour TWA (PEL)*

**200 ppm** *Ceiling*

[**Carbon Dioxide (CO₂)** Gases & VOCs](https://aethair.io/parameters/co2/)

**5000 ppm** *8-hour TWA (PEL)*

**30000 ppm** *STEL*

[**Hydrogen Sulfide (H₂S)** Gases & VOCs](https://aethair.io/parameters/h2s/)

**10 ppm** *8-hour TWA (PEL)*

**15 ppm** *STEL*

**50 ppm** *Ceiling*

[**Sulfur Dioxide (SO₂)** Gases & VOCs](https://aethair.io/parameters/so2/)

**2 ppm** *8-hour TWA (PEL)*

**5 ppm** *STEL*

[**Nitric Oxide (NO)** Gases & VOCs](https://aethair.io/parameters/no/)

**25 ppm** *8-hour TWA (PEL)*

[**Nitrogen Dioxide (NO₂)** Gases & VOCs](https://aethair.io/parameters/no2/)

**1 ppm** *STEL*

[**Ozone (O₃)** Gases & VOCs](https://aethair.io/parameters/o3/)

**0.1 ppm** *8-hour TWA (PEL)*

**0.3 ppm** *STEL*

[**Ammonia (NH₃)** Gases & VOCs](https://aethair.io/parameters/nh3/)

**25 ppm** *8-hour TWA (PEL)*

**35 ppm** *STEL*

[**Chlorine (Cl₂)** Gases & VOCs](https://aethair.io/parameters/cl2/)

**0.5 ppm** *8-hour TWA (PEL)*

**1 ppm** *STEL*

[**Mercury (Hg)** Gases & VOCs](https://aethair.io/parameters/hg/)

**0.025 mg/m³** *8-hour TWA (PEL)* metallic and inorganic mercury

**0.1 mg/m³** *Ceiling* metallic and inorganic mercury

[**Hydrogen Chloride (HCl)** Gases & VOCs](https://aethair.io/parameters/hcl/)

**0.3 ppm** *8-hour TWA (PEL)*

**2 ppm** *Ceiling*

[**Hydrogen Fluoride (HF)** Gases & VOCs](https://aethair.io/parameters/hf/)

**0.4 ppm** *8-hour TWA (PEL)* as F

**1 ppm** *STEL* as F

[**BTEX / speciated VOC** Gases & VOCs](https://aethair.io/parameters/btex/)

**1 ppm** *8-hour TWA (PEL)* benzene (see also section 5218)

**5 ppm** *STEL* benzene

Who it applies to

## Who Must Comply

Employers in California. Where Cal/OSHA's limit is stricter than the federal PEL, the California value applies; OSHA's annotated PEL tables reproduce the Cal/OSHA values alongside the federal ones for comparison.

Monitoring

## How Monitoring Demonstrates Compliance

Each limit is compared with exposure over its own period: the 8-hour TWA for the PEL, 15 minutes for the STEL, any moment for a ceiling. Continuous monitoring is what shows a STEL or ceiling being approached, which a shift-average sample cannot; personal sampling in the breathing zone documents individual exposure.

[Customize this configuration](https://aethair.io/build/?params=co,co2,h2s,so2,no,no2,o3,nh3,cl2,hg,hcl,hf,btex)

### Who measures each parameter

| Parameter | Aethair PRO | Aethair IAQ | External |
| - | - | - | - |
| [Carbon Monoxide (CO)](https://aethair.io/parameters/co/) | CO (electrochemical), MultiGas+ +1 cartridges | — | [3 instruments](https://aethair.io/parameters/co/) via Thiamis |
| [Carbon Dioxide (CO₂)](https://aethair.io/parameters/co2/) | CO₂ (dual NDIR), CO₂ (self-calibrating NDIR) cartridges | Built in | [2 instruments](https://aethair.io/parameters/co2/) via Thiamis |
| [Hydrogen Sulfide (H₂S)](https://aethair.io/parameters/h2s/) | H₂S cartridge | — | [4 instruments](https://aethair.io/parameters/h2s/) via Thiamis |
| [Sulfur Dioxide (SO₂)](https://aethair.io/parameters/so2/) | MultiSense, SO₂ cartridges | — | [1 instrument](https://aethair.io/parameters/so2/) via Thiamis |
| [Nitric Oxide (NO)](https://aethair.io/parameters/no/) | NO cartridge | — | [1 instrument](https://aethair.io/parameters/no/) via Thiamis |
| [Nitrogen Dioxide (NO₂)](https://aethair.io/parameters/no2/) | NO₂, MultiSense +1 cartridges | — | [1 instrument](https://aethair.io/parameters/no2/) via Thiamis |
| [Ozone (O₃)](https://aethair.io/parameters/o3/) | O₃+NO₂ cartridge | — | [1 instrument](https://aethair.io/parameters/o3/) via Thiamis |
| [Ammonia (NH₃)](https://aethair.io/parameters/nh3/) | — | — | [1 instrument](https://aethair.io/parameters/nh3/) via Thiamis |
| [Chlorine (Cl₂)](https://aethair.io/parameters/cl2/) | — | — | [1 instrument](https://aethair.io/parameters/cl2/) via Thiamis |
| [Mercury (Hg)](https://aethair.io/parameters/hg/) | — | — | [1 instrument](https://aethair.io/parameters/hg/) via Thiamis |
| [Hydrogen Chloride (HCl)](https://aethair.io/parameters/hcl/) | HCl cartridge | — | — |
| [Hydrogen Fluoride (HF)](https://aethair.io/parameters/hf/) | HF cartridge | — | — |
| [BTEX / speciated VOC](https://aethair.io/parameters/btex/) | — | — | [1 instrument](https://aethair.io/parameters/btex/) via Thiamis |

Devices

## Devices That Cover Cal/OSHA PEL

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

[**Aethair PRO** Built in + Aethair O₃+NO₂, Aethair CO (electrochemical), Custom MultiSense (CO₂, H₂S, SO₂) 6 of 13: CO, CO₂, H₂S, SO₂, NO₂, O₃](https://aethair.io/products/pro/)

Covers part of it (combine on one Thiamis)

[**RAE** Gas Detectors 8 of 13: Cl₂, CO, CO₂, H₂S, NH₃, NO, NO₂, SO₂](https://aethair.io/sensors/rae-gas-detectors/) [**TSI GM460** Gas Detectors 2 of 13: CO, H₂S](https://aethair.io/sensors/tsi-gas-detectors/) [**RKI Instruments GX6000** Gas Detectors 2 of 13: CO, H₂S](https://aethair.io/sensors/rki-instruments-gas-detectors/) [**AMETEK Brookfield Jerome** Specialty Air Analyzers 2 of 13: H₂S, Mercury](https://aethair.io/sensors/ametek-brookfield-specialty-air-analyzers/) [**Defiant Technologies FROG** Specialty Air Analyzers 1 of 13: BTEX / speciated VOC](https://aethair.io/sensors/defiant-technologies-specialty-air-analyzers/) [**Particles Plus** Particulate & Dust Monitors 1 of 13: CO₂](https://aethair.io/sensors/particles-plus-particulate-dust-monitors/) [**2B Technologies POM** Specialty Air Analyzers 1 of 13: O₃](https://aethair.io/sensors/2b-technologies-specialty-air-analyzers/)

Solutions

## Solutions Judged Against Cal/OSHA PEL

### [Occupational Safety & Industrial Hygiene](https://aethair.io/solutions/occupational-safety/)

Worker exposure, confined space, and heat stress

[All solutions](https://aethair.io/solutions/)

Article Library

## Articles on Cal/OSHA PEL

### [Ozone Exposure Limits and Monitoring: OSHA and NAAQS](https://aethair.io/resources/ozone-monitoring-exposure-limits/)

OSHA's ozone PEL is 0.1 ppm as an 8-hour TWA. How NIOSH, ACGIH, and the 70 ppb NAAQS compare, and why ozone needs short-interval monitoring.

[All articles](https://aethair.io/resources/)

Questions

## Cal/OSHA PEL FAQ

What is the Cal/OSHA PEL for carbon monoxide?

25 ppm as an 8-hour time-weighted average, with a ceiling of 200 ppm, stricter than the federal [OSHA PEL](https://aethair.io/resources/osha-air-quality-standards-compliance/) of 50 ppm.

What does Cal/OSHA set for ozone?

A permissible exposure limit of 0.1 ppm as an 8-hour TWA and a short-term exposure limit of 0.3 ppm.

Which limit applies in California, federal or Cal/OSHA?

California employers follow Cal/OSHA's Table AC-1, which is stricter than the federal limits for many substances.