Measurements · Radiation & Light

UV Index

Also known as ultraviolet

The UV index is the standard scale for the strength of the sun's ultraviolet radiation at the ground, a single unitless number.

Schedule a callConfigure UV Index Monitoring

What it is

What is the UV index?

The UV index is the standard scale for the strength of the sun's ultraviolet radiation at the ground, a single unitless number. On this platform it is a weather-station reading, from the Davis stations that carry a UV sensor.

Among the Davis models in the sensor catalog, the UV index is reported by the Vantage Pro2 (whose solar and UV sensors are optional) and by two legacy EnviroMonitor consoles: the GroWeather, an agricultural station that also reads solar radiation, soil, and leaf sensors, and the HealthEnviroMonitor, a heat-stress and comfort station. The compact Vantage Vue has no solar or UV sensor, and the other legacy consoles (the Weather Wizard, Weather Monitor, Perception, and EnergyMonitor) do not report UV.

How it is measured

How UV Index Is Measured

A Davis station connects to a Thiamis gateway over RS-232. On connection the driver asks the station for its model, then polls it for live readings, so a station reports the UV index only when it is a model that carries the sensor and the sensor is fitted.

An instrument on Thiamis1

A third-party instrument connected to a Thiamis gateway, reporting into the same Environet account.

Every device and option that measures UV Index 1

Device / optionTypeBase platformMeasures
Davis · Davis Wizard III, Davis Wizard II, Davis Monitor…
Weather Stations
Thiamis

Configure UV Index Monitoring

Related

Questions

UV Index FAQ

Which Davis stations report the UV index?

The Vantage Pro2 with its optional UV sensor, and the legacy GroWeather and HealthEnviroMonitor consoles. The Vantage Vue has no UV sensor.

What unit is the UV index in?

None: it is a unitless index.

How does a Davis station connect?

Over RS-232 to a Thiamis gateway, which identifies the model on connection and then polls it for live readings.