Aethair monitors

Aethair PRO

Industrial-Grade Customizable Environmental Monitor for Indoor and Outdoor Use

Aethair PRO continuously measures PM1, PM2.5, PM10, and total PM, plus temperature, humidity, pressure, sound, and light. It holds two hot-swappable gas sensor cartridges (from 17 options covering 12 gases), a MultiSense cartridge in its MultiSense socket, and a differential-pressure cartridge in its expansion socket. Built-in 4G LTE with cellular data included, and the Solar Panel Bracket for off-grid power, put it at fencelines, on sites, and in operator cabs, with alerts and reports against NAAQS levels, OSHA limits, or site action levels, each on its own averaging period. See the outdoor and ambient air quality monitoring solution built around it.
13built-in parameters
2 + 2cartridge sockets
19cartridges

Schedule an Aethair PRO DemoBuild a Configuration

Aethair PRO air quality monitor mounted on a white brick wall
Aethair PRO, the industrial monitor for indoors and outdoors
Two Aethair PRO monitors, one open to show its two gas sensor cartridge sockets, with VOC, NO₂, and CO₂ gas sensor cartridges beside them.

Sensors

An Industrial Air Quality Monitor Built for Adaptability

90° laser particle detection (PM1, PM2.5, and PM10), hot-swappable gas sensor cartridges, a MultiSense cartridge, and a differential-pressure cartridge, in an aluminum alloy enclosure for indoor or outdoor operation, with Magnet, Wall / Locking, and Strap adapters for its mount and the optional Solar Panel Bracket. The built-in sensors and every cartridge are listed below, each linked to its catalog page.

Where it is used

Where Aethair PRO Runs

One device, set up for each by the cartridges it carries. Each tile opens its solution page.

In the catalog

More Solutions Built on Aethair PRO

Every solution whose recommended configuration uses Aethair PRO, beyond the sites above.

What you get from it

What You Get From Aethair PRO

Every reading goes to the Aethair Cloud and appears in Environet. Each outcome below is a product you can read about.

Your data, stored until delivered

Aethair PRO caches readings on the device until they are delivered, so a connectivity outage delays readings instead of dropping them, and raw readings are stored exactly as the device sent them. Every reading is encrypted in transit to the Aethair Cloud and platform access is role-based. Live and historical readings export as JSON or CSV through the Environet API (OpenAPI 3.2). You own your devices and data, can grant partners controlled access, and readings are kept for as long as you need them (at least two years after a project ends) and deleted only at your request.

Calibrated, with little to maintain

Aethair PRO is calibrated before shipping against NIST-traceable reference standards and ships with a Performance Certificate: for each sensor checked against a reference device, it names that device and gives the correlation (R and R²) and the p75, p90, and p95 errors (an example, from an Aethair IAQ). There is no filter to change. Servicing means exchanging a pre-calibrated gas sensor cartridge when it is due, with a screwdriver and no recalibration on site, and firmware and configuration updates arrive over the air from Environet.

One account for every site

Every Aethair PRO, at every site, sits in the same Environet account as Aethair IAQ and Thiamis-connected sensors: one console, the same alerts, reports, and dashboards for every device.

What it measures

Built-In Sensors

ParameterRangeResolutionWhat it measures
PM1µg/m³—1 µg/m³Submicron particulate ≤1 µm, the fraction that penetrates deepest into the lungs. Measured by 90° laser light-scattering, in µg/m³.
PM2.5µg/m³0–1000 µg/m³1 µg/m³Fine particulate ≤2.5 µm, the headline health metric behind NAAQS and WHO limits. 90° laser light-scattering, µg/m³.
PM10µg/m³0–1000 µg/m³1 µg/m³Coarse particulate ≤10 µm: dust, pollen, and road grit. Measured by 90° laser light-scattering, in µg/m³.
Total PM / Mass Conc.µg/m³0–2000 µg/m³1 µg/m³Total particulate mass the optical sensor reports across its size bins (the device's "PM" channel; the spec sheet calls it TSP), µg/m³. An optical sensor under-counts the largest particles, so this is not a gravimetric TSP measurement.
Particle Count (by size)particles≥0.3 µm, ≥0.5 µm, ≥1.0 µm, ≥2.5 µm, ≥5.0 µm, ≥10.0 µm——Raw particle counts in six optical size bins (≥0.3, ≥0.5, ≥1.0, ≥2.5, ≥5.0, and ≥10.0 µm) from the laser counter, used to derive the PM mass fractions.
Air Temperature°C / °F-20 to 70 °C0.1 °CAir temperature, reported in °C or °F.
Relative Humidity%0–90 %0.1 %Relative humidity, %.
Barometric PressurekPa30–110 kPa—Barometric pressure, kPa.
Dew Point°C / °F——Dew point (the temperature at which air becomes saturated), derived from temperature and humidity. °C or °F.
Heat Index°C / °F——Heat index (apparent temperature), derived from temperature and humidity. °C or °F.
Sound Pressure Level (SPL)dB40–120 dB1 dBSound pressure level: instantaneous ambient noise, dB.
Equivalent Continuous Level (Leq)dB40–120 dB1 dBEquivalent continuous sound level (Leq): time-averaged ambient noise, dB.
Illuminance / Lightlums0–10,000—Ambient light level on the sensor's own scale.

Hot-swappable

Gas, MultiSense, and Expansion Cartridges

Aethair PRO has three kinds of cartridge socket, and each kind takes its own cartridge type. A full monitor carries two gas sensor cartridges, the MultiSense cartridge, and the differential-pressure cartridge.

Three Aethair PRO gas sensor cartridges, for NO, CH₄, and NO₂, each labelled with its gas and color band.
Aethair PRO with its cover off: two gas sensor cartridges beside the two gas sensor cartridge sockets, and the MultiSense cartridge beside the MultiSense socket.
The underside of Aethair PRO with the expansion socket highlighted, beside the power cartridge and the cable for the differential-pressure accessory.
  • 2× Gas sockets. Any two of 17 pre-calibrated, hot-swappable cartridges, exchanged with a screwdriver and no recalibration on site.
  • 1× MultiSense socket, inside, next to the gas sockets: the MultiSense cartridge, or a Custom MultiSense built to order for the kit.
  • 1× Expansion socket takes the differential-pressure cartridge.
CartridgeDescriptionMeasures & specs
Aethair CO (electrochemical) Gas 0d01Carbon monoxide cartridge. An amperometric electrochemical CO cell with a solid, non-aqueous electrolyte (the long-life, low-power sensing element used in residential and commercial CO alarms), for combustion safety, garages, and workplace air monitoring.
Carbon Monoxide (CO)0-1000 ppm · res. 1 ppm
Aethair CO₂ (dual NDIR) Gas 0d02Carbon dioxide cartridge. Dual-thermopile NDIR (non-dispersive infrared) sensing measures CO₂ with no chemical consumables, for demand-controlled ventilation, HVAC, and indoor air quality.
Carbon Dioxide (CO₂)0-5000 ppm · res. 1 ppm
Aethair VOC (ppm PID) Gas 0d03Total VOC cartridge (ppm range). A 10.6 eV photoionization detector (PID) ionizes volatile organic compounds for direct ppm readings across a wide range. Used for industrial hygiene, leak detection, and fenceline monitoring of solvent, fuel, and off-gassing vapors.
VOC (Total)0-4000 ppm · res. 0.1 ppm
Aethair CO₂ (self-calibrating NDIR) Gas 0d04Carbon dioxide cartridge. NDIR (non-dispersive infrared) sensing with automatic background self-calibration for maintenance-free CO₂ measurement in demand-controlled ventilation and indoor air quality.
Carbon Dioxide (CO₂)0-5000 ppm · res. 1 ppm
Aethair NO₂ Gas 0d05Nitrogen dioxide cartridge. Four-electrode electrochemical sensing resolves NO₂ down to parts-per-billion, for roadside traffic, combustion, and ambient air-quality networks.
Nitrogen Dioxide (NO₂)0-20 ppm · res. 20 ppb
Aethair CH₄ Gas 0d0aMethane cartridge. Molecular Property Spectrometer (MPS) MEMS sensing, poison-immune and factory-calibrated for life, for combustible-gas monitoring in %LEL.
Methane (CH₄)0-100 %LEL · res. 1 %LEL
Aethair O₂ Gas 0d11Oxygen cartridge. A self-powered galvanic electrochemical cell with instant-on response measures O₂ from 0 to 30%, for oxygen depletion and enrichment monitoring.
Oxygen (O₂)0-30 % · res. 0.1 %
Aethair VOC (ppb PID) Gas 0d13Total VOC cartridge (ppb range). A high-sensitivity 10.6 eV photoionization detector (PID) resolves volatile organic compounds to single-digit ppb, for low-level VOC monitoring in indoor air quality and fugitive-emissions surveillance.
VOC (Total)0-40 ppm · res. 1 ppb
Aethair NO Gas 0d15Nitric oxide cartridge. Biased four-electrode electrochemical sensing resolves NO to parts-per-billion, for combustion, NOₓ, and ambient air-quality monitoring.
Nitric Oxide (NO)0-20 ppm · res. 15 ppb
Aethair MultiGas+ Gas 0d16Combination cartridge. Metal-oxide semiconductor (MOS) sensing tracks carbon monoxide, methane, and total VOC from a compact element, for combustible-gas safety and indoor air-quality monitoring. A MOS element responds to all three gases and to humidity, so its readings are indicative trends rather than selective measurements.
Methane (CH₄)0-10000 ppm · res. 10 ppm
Carbon Monoxide (CO)0-1000 ppm · res. 1 ppm
VOC (Total)0-100 ppm · res. 1 ppm
Aethair VOC (ppb PID, wide range) Gas 0d25Total VOC cartridge (ppb range). Photoionization detection (PID) resolves volatile organic compounds to parts-per-billion, for low-level VOC monitoring in indoor air and process environments.
VOC (Total)0-4000 ppm · res. 1 ppb
Aethair CO (ppb, four-electrode) Gas 0d35Carbon monoxide cartridge. Four-electrode electrochemical sensing resolves CO from parts-per-billion up to 1000 ppm, for ambient air-quality and traffic-pollution monitoring.
Carbon Monoxide (CO)0-1000 ppm · res. 4 ppb
Aethair O₃+NO₂ Gas 0d45Ozone cartridge. Four-electrode electrochemical sensing measures oxidizing gases (ozone plus nitrogen dioxide) and reports one combined O₃+NO₂ value (shown under both parameters), for ambient air-quality monitoring.
Nitrogen Dioxide (NO₂)0-20 ppm · res. 15 ppb
Ozone (O₃)0-20 ppm · res. 15 ppb
Aethair SO₂ Gas 0d55Sulfur dioxide cartridge. Four-electrode electrochemical sensing resolves SO₂ from parts-per-billion up to 100 ppm, for combustion, industrial-emissions, and ambient air-quality monitoring.
Sulfur Dioxide (SO₂)0-100 ppm · res. 5 ppb
Aethair H₂S Gas 0d65Hydrogen sulfide cartridge. Filtered four-electrode electrochemical sensing resolves H₂S to parts per billion, for wastewater, odor, oil & gas, and safety monitoring.
Hydrogen Sulfide (H₂S)0-50 ppm · res. 5 ppb
Aethair HCl Gas 0d75Hydrogen chloride cartridge. A large-electrolyte electrochemical sensor built for high-humidity, corrosive environments detects HCl for semiconductor etch, exhaust-scrubber, and incineration monitoring.
Hydrogen Chloride (HCl)0-30 ppm · res. 0.5 ppm
Aethair HF Gas 0d85Hydrogen fluoride cartridge. Three-electrode electrochemical sensing detects HF at trace levels, for aluminum smelting, glass etching, semiconductor, and refining safety.
Hydrogen Fluoride (HF)0-10 ppm · res. 0.05 ppm
Aethair MultiSense MultiSense 0d09Multi-gas sensor cartridge. Simultaneous electrochemical detection of sulfur dioxide, nitrogen dioxide, and formaldehyde at parts-per-billion resolution, for ambient and indoor air-quality monitoring.
Nitrogen Dioxide (NO₂)0-20 ppm · res. 20 ppb
Formaldehyde (CH₂O)0-10 ppm · res. 10 ppb
Sulfur Dioxide (SO₂)0-20 ppm · res. 10 ppb
Aethair Diff. Pressure Expansion 0d08Differential-pressure cartridge for the Aethair PRO expansion socket, for room-to-room pressure monitoring in cleanrooms and containment. A gauge sensor reads 0–10 kPa, with the higher-pressure side connected to its port.

How it is built

Aethair PRO Hardware

Sensor ranges and resolutions are in the tables above. All other Aethair PRO specifications are listed below.

Show the full specification sheet

General

Input voltageUSB-C, 110–240 VAC
Power1 W approx. (configuration dependent); built-in battery and charger, about 24 h in normal mode and up to 72 h in power-save mode (15-minute reporting); optional Solar Panel Bracket
Operating temperature−30 °C to 70 °C (−22 °F to 158 °F)
Accelerometer16 g, 13-bit resolution
Dimensions (L×W×D)9.625 in × 4.5 in × 4.5 in (244 mm × 114 mm × 114 mm)
Weight1.72 lb (0.78 kg)
MountingWall, locking, magnetic, and pole mounts; Solar Panel Bracket and tripod mounts also available
CertificationsCE, FCC
Particle sensorDual laser, 90° light scattering; PM1, PM2.5, PM10, TSP
On-device alertsVisual and audio
ReportingEvery parameter published once a minute, as measured
UpdatesFirmware and configuration over the air, from Environet

Communications

Cellular4G LTE / 3G / 2G
WiFi802.11 b/g/n
BluetoothBluetooth 4.0
MeshZigbee
GPSA-GPS
AntennaBuilt-in
SIM cardBuilt-in; cellular data included, no network fee

Source: Aethair PRO Technical Specifications (Rev. 3.3, September 2026).

The back of an Aethair PRO with its mount highlighted, and the three adapters it takes: Magnet, Wall / Locking, and Strap.

Mounting

Choose How Aethair PRO Mounts

The mount on the back of Aethair PRO takes three interchangeable adapters, so the same monitor can go on steel, a wall, or a pole.

  • Magnet Adapter: holds to steel (equipment, cabs, metal walls, and doors), or seats onto the optional round Wall Bracket.
  • Wall / Locking Adapter: fits its slotted Wall Bracket and locks the monitor in place.
  • Strap Adapter: takes a hose clamp around a pole, pipe, or rail.

Outdoors, Aethair PRO can run on solar power with the optional Solar Panel Bracket.

Still deciding?

The Other Aethair Devices: Aethair IAQ and Thiamis

Standards

Monitor for These Standards with Aethair PRO

Monitor with built-in sensors:

Monitor with cartridges:

Guidance that references these measurements without setting a limit:

Article Library

Reading for Aethair PRO Deployments

Guides that put Aethair PRO to work: the programs, standards, and sites it is used for.

All articles

Questions

Aethair PRO FAQ

How is Aethair PRO used in EHS programs?
Set thresholds in Environet on the averaging period each limit is defined over: a 24-hour or annual average for the NAAQS PM2.5 level, an 8-hour TWA for an OSHA PEL on a gas measured by a sensor cartridge, and 15 minutes for a dust action level. Any window from 5 minutes to 30 days is available, and reports apply the same averages. As an area monitor, Aethair PRO is a continuous screen that shows where and when levels approach those limits. OSHA PEL compliance itself rests on personal breathing-zone sampling, and NAAQS attainment on FRM/FEM data. Where a permit calls for a reference or near-reference instrument, such as a Met One E-BAM, that instrument connects through Thiamis into the same account.
Can it run off-grid?
Yes. With the Solar Panel Bracket, it runs on solar power where there is no mains, mounted on a pole or a tripod. The built-in battery carries it through a loss of power: about 24 hours in normal mode, or up to 72 hours in power-save mode, which reports every 15 minutes.
What does field reconfiguration involve?
Pre-calibrated cartridges change with a screwdriver, with no recalibration; the device keeps reporting on its built-in SIM throughout. Because it carries its own cellular connection, it needs no local network, no Wi-Fi onboarding, and no IT involvement at the site.
Who installs Aethair PRO?
Your own team or a partner from Aethair's network. No special license is needed, and the process is simple: mount the monitor, power it on, and it starts reporting over its own cellular link, with data included and no network fee. Where coverage is weak, it can join the site's Wi-Fi instead.
How is Aethair PRO bought?
The hardware is a one-time purchase: the monitors and gateway with their sensors, cartridges, and accessories. The platform is an annual subscription on a one- to three-year contract that covers every platform feature. Cellular data and data hosting are included, with no network fee. It starts with a 30-minute call: you tell us about your application, then we demo the solution for it.

Put Aethair PRO on Your Site

Schedule an Aethair PRO DemoBuild a monitoring configuration Outdoor & ambient monitoring solution Case study: cabin monitoring at Drummond Gas sensor cartridge specifications Choosing between Aethair PRO, Aethair IAQ, and Thiamis

A 30-minute call: you tell us about your application, then we demo the solution for it.

Used by teams at