Aethair monitors
Aethair PRO
Industrial-Grade Customizable Environmental Monitor for Indoor and Outdoor Use


Sensors
An Industrial Air Quality Monitor Built for Adaptability
90° laser particle detection (PM1, PM2.5, and PM10), hot-swappable gas sensor cartridges, a MultiSense cartridge, and a differential-pressure cartridge, in an aluminum alloy enclosure for indoor or outdoor operation, with Magnet, Wall / Locking, and Strap adapters for its mount and the optional Solar Panel Bracket. The built-in sensors and every cartridge are listed below, each linked to its catalog page.
Where it is used
Where Aethair PRO Runs
One device, set up for each by the cartridges it carries. Each tile opens its solution page.

Cabins and Equipment Fleets
Cabin pressure, CO₂, and VOCs in mining and heavy-equipment cabs, reported to ISO 23875, and in rail and transit fleets, with the same monitor in the cab and at the depot; Drummond Company runs Aethair PRO across its mining vehicle fleet in Colombia.

Outdoor and Ambient Networks
PM2.5, PM10, and total PM with gas sensor cartridges over 4G LTE, solar-powered where there is no mains, for city, roadside, and fenceline networks.

Wildfire Smoke
PM2.5 and PM10 from the built-in particle sensor across a regional network, solar-powered where there is no mains, with alerts at the thresholds you set.

Perimeter Monitoring
Dust, gases, and ppb-level VOCs at fencelines and site boundaries, with reports for compliance and community oversight.

Commercial Buildings
CO in garages and workplace air, room-to-room pressure via the differential-pressure cartridge, plus PM, noise, and comfort.

Medical Facilities
Aethair PRO combines built-in particulate, temperature, and humidity sensors with a VOC cartridge, plus a differential-pressure cartridge for rooms that need a pressure record. The CMS-2567 report checks temperature, humidity, and pressure against ASHRAE 170 for the surveyor.
In the catalog
More Solutions Built on Aethair PRO
Every solution whose recommended configuration uses Aethair PRO, beyond the sites above.
Cleanrooms, Labs & Manufacturing
Particle counting and controlled environments
HVAC & Building Management
Monitor ventilation and filtration, with data for your BMS
Landfill, Biogas & Odor
Methane, H₂S, and odor complaint response
Occupational Safety & Industrial Hygiene
Worker exposure, confined space, and heat stress
Oil & Gas / Petrochemical
Fence-line VOC, H₂S, and methane leak detection
What you get from it
What You Get From Aethair PRO
Every reading goes to the Aethair Cloud and appears in Environet. Each outcome below is a product you can read about.
What it measures
Built-In Sensors
| Parameter | Range | Resolution | What it measures |
|---|---|---|---|
| PM1µg/m³ | — | 1 µg/m³ | Submicron particulate ≤1 µm, the fraction that penetrates deepest into the lungs. Measured by 90° laser light-scattering, in µg/m³. |
| PM2.5µg/m³ | 0–1000 µg/m³ | 1 µg/m³ | Fine particulate ≤2.5 µm, the headline health metric behind NAAQS and WHO limits. 90° laser light-scattering, µg/m³. |
| PM10µg/m³ | 0–1000 µg/m³ | 1 µg/m³ | Coarse particulate ≤10 µm: dust, pollen, and road grit. Measured by 90° laser light-scattering, in µg/m³. |
| Total PM / Mass Conc.µg/m³ | 0–2000 µg/m³ | 1 µg/m³ | Total particulate mass the optical sensor reports across its size bins (the device's "PM" channel; the spec sheet calls it TSP), µg/m³. An optical sensor under-counts the largest particles, so this is not a gravimetric TSP measurement. |
| Particle Count (by size)particles≥0.3 µm, ≥0.5 µm, ≥1.0 µm, ≥2.5 µm, ≥5.0 µm, ≥10.0 µm | — | — | Raw particle counts in six optical size bins (≥0.3, ≥0.5, ≥1.0, ≥2.5, ≥5.0, and ≥10.0 µm) from the laser counter, used to derive the PM mass fractions. |
| Air Temperature°C / °F | -20 to 70 °C | 0.1 °C | Air temperature, reported in °C or °F. |
| Relative Humidity% | 0–90 % | 0.1 % | Relative humidity, %. |
| Barometric PressurekPa | 30–110 kPa | — | Barometric pressure, kPa. |
| Dew Point°C / °F | — | — | Dew point (the temperature at which air becomes saturated), derived from temperature and humidity. °C or °F. |
| Heat Index°C / °F | — | — | Heat index (apparent temperature), derived from temperature and humidity. °C or °F. |
| Sound Pressure Level (SPL)dB | 40–120 dB | 1 dB | Sound pressure level: instantaneous ambient noise, dB. |
| Equivalent Continuous Level (Leq)dB | 40–120 dB | 1 dB | Equivalent continuous sound level (Leq): time-averaged ambient noise, dB. |
| Illuminance / Lightlums | 0–10,000 | — | Ambient light level on the sensor's own scale. |
Hot-swappable
Gas, MultiSense, and Expansion Cartridges
Aethair PRO has three kinds of cartridge socket, and each kind takes its own cartridge type. A full monitor carries two gas sensor cartridges, the MultiSense cartridge, and the differential-pressure cartridge.



- 2× Gas sockets. Any two of 17 pre-calibrated, hot-swappable cartridges, exchanged with a screwdriver and no recalibration on site.
- 1× MultiSense socket, inside, next to the gas sockets: the MultiSense cartridge, or a Custom MultiSense built to order for the kit.
- 1× Expansion socket takes the differential-pressure cartridge.
| Cartridge | Description | Measures & specs |
|---|---|---|
0d01 | Carbon monoxide cartridge. An amperometric electrochemical CO cell with a solid, non-aqueous electrolyte (the long-life, low-power sensing element used in residential and commercial CO alarms), for combustion safety, garages, and workplace air monitoring. | Carbon Monoxide (CO)0-1000 ppm · res. 1 ppm |
0d02 | Carbon dioxide cartridge. Dual-thermopile NDIR (non-dispersive infrared) sensing measures CO₂ with no chemical consumables, for demand-controlled ventilation, HVAC, and indoor air quality. | Carbon Dioxide (CO₂)0-5000 ppm · res. 1 ppm |
0d03 | Total VOC cartridge (ppm range). A 10.6 eV photoionization detector (PID) ionizes volatile organic compounds for direct ppm readings across a wide range. Used for industrial hygiene, leak detection, and fenceline monitoring of solvent, fuel, and off-gassing vapors. | VOC (Total)0-4000 ppm · res. 0.1 ppm |
0d04 | Carbon dioxide cartridge. NDIR (non-dispersive infrared) sensing with automatic background self-calibration for maintenance-free CO₂ measurement in demand-controlled ventilation and indoor air quality. | Carbon Dioxide (CO₂)0-5000 ppm · res. 1 ppm |
0d05 | Nitrogen dioxide cartridge. Four-electrode electrochemical sensing resolves NO₂ down to parts-per-billion, for roadside traffic, combustion, and ambient air-quality networks. | Nitrogen Dioxide (NO₂)0-20 ppm · res. 20 ppb |
0d0a | Methane cartridge. Molecular Property Spectrometer (MPS) MEMS sensing, poison-immune and factory-calibrated for life, for combustible-gas monitoring in %LEL. | Methane (CH₄)0-100 %LEL · res. 1 %LEL |
0d11 | Oxygen cartridge. A self-powered galvanic electrochemical cell with instant-on response measures O₂ from 0 to 30%, for oxygen depletion and enrichment monitoring. | Oxygen (O₂)0-30 % · res. 0.1 % |
0d13 | Total VOC cartridge (ppb range). A high-sensitivity 10.6 eV photoionization detector (PID) resolves volatile organic compounds to single-digit ppb, for low-level VOC monitoring in indoor air quality and fugitive-emissions surveillance. | VOC (Total)0-40 ppm · res. 1 ppb |
0d15 | Nitric oxide cartridge. Biased four-electrode electrochemical sensing resolves NO to parts-per-billion, for combustion, NOₓ, and ambient air-quality monitoring. | Nitric Oxide (NO)0-20 ppm · res. 15 ppb |
0d16 | Combination cartridge. Metal-oxide semiconductor (MOS) sensing tracks carbon monoxide, methane, and total VOC from a compact element, for combustible-gas safety and indoor air-quality monitoring. A MOS element responds to all three gases and to humidity, so its readings are indicative trends rather than selective measurements. | Methane (CH₄)0-10000 ppm · res. 10 ppm Carbon Monoxide (CO)0-1000 ppm · res. 1 ppm VOC (Total)0-100 ppm · res. 1 ppm |
0d25 | Total VOC cartridge (ppb range). Photoionization detection (PID) resolves volatile organic compounds to parts-per-billion, for low-level VOC monitoring in indoor air and process environments. | VOC (Total)0-4000 ppm · res. 1 ppb |
0d35 | Carbon monoxide cartridge. Four-electrode electrochemical sensing resolves CO from parts-per-billion up to 1000 ppm, for ambient air-quality and traffic-pollution monitoring. | Carbon Monoxide (CO)0-1000 ppm · res. 4 ppb |
0d45 | Ozone cartridge. Four-electrode electrochemical sensing measures oxidizing gases (ozone plus nitrogen dioxide) and reports one combined O₃+NO₂ value (shown under both parameters), for ambient air-quality monitoring. | Nitrogen Dioxide (NO₂)0-20 ppm · res. 15 ppb Ozone (O₃)0-20 ppm · res. 15 ppb |
0d55 | Sulfur dioxide cartridge. Four-electrode electrochemical sensing resolves SO₂ from parts-per-billion up to 100 ppm, for combustion, industrial-emissions, and ambient air-quality monitoring. | Sulfur Dioxide (SO₂)0-100 ppm · res. 5 ppb |
0d65 | Hydrogen sulfide cartridge. Filtered four-electrode electrochemical sensing resolves H₂S to parts per billion, for wastewater, odor, oil & gas, and safety monitoring. | Hydrogen Sulfide (H₂S)0-50 ppm · res. 5 ppb |
0d75 | Hydrogen chloride cartridge. A large-electrolyte electrochemical sensor built for high-humidity, corrosive environments detects HCl for semiconductor etch, exhaust-scrubber, and incineration monitoring. | Hydrogen Chloride (HCl)0-30 ppm · res. 0.5 ppm |
0d85 | Hydrogen fluoride cartridge. Three-electrode electrochemical sensing detects HF at trace levels, for aluminum smelting, glass etching, semiconductor, and refining safety. | Hydrogen Fluoride (HF)0-10 ppm · res. 0.05 ppm |
0d09 | Multi-gas sensor cartridge. Simultaneous electrochemical detection of sulfur dioxide, nitrogen dioxide, and formaldehyde at parts-per-billion resolution, for ambient and indoor air-quality monitoring. | Nitrogen Dioxide (NO₂)0-20 ppm · res. 20 ppb Formaldehyde (CH₂O)0-10 ppm · res. 10 ppb Sulfur Dioxide (SO₂)0-20 ppm · res. 10 ppb |
0d08 | Differential-pressure cartridge for the Aethair PRO expansion socket, for room-to-room pressure monitoring in cleanrooms and containment. A gauge sensor reads 0–10 kPa, with the higher-pressure side connected to its port. | Differential Pressure0-10000 Pa |
How it is built
Aethair PRO Hardware
Sensor ranges and resolutions are in the tables above. All other Aethair PRO specifications are listed below.
Show the full specification sheet
General
| Input voltage | USB-C, 110–240 VAC |
|---|---|
| Power | 1 W approx. (configuration dependent); built-in battery and charger, about 24 h in normal mode and up to 72 h in power-save mode (15-minute reporting); optional Solar Panel Bracket |
| Operating temperature | −30 °C to 70 °C (−22 °F to 158 °F) |
| Accelerometer | 16 g, 13-bit resolution |
| Dimensions (L×W×D) | 9.625 in × 4.5 in × 4.5 in (244 mm × 114 mm × 114 mm) |
| Weight | 1.72 lb (0.78 kg) |
| Mounting | Wall, locking, magnetic, and pole mounts; Solar Panel Bracket and tripod mounts also available |
| Certifications | CE, FCC |
| Particle sensor | Dual laser, 90° light scattering; PM1, PM2.5, PM10, TSP |
| On-device alerts | Visual and audio |
| Reporting | Every parameter published once a minute, as measured |
| Updates | Firmware and configuration over the air, from Environet |
Communications
| Cellular | 4G LTE / 3G / 2G |
|---|---|
| WiFi | 802.11 b/g/n |
| Bluetooth | Bluetooth 4.0 |
| Mesh | Zigbee |
| GPS | A-GPS |
| Antenna | Built-in |
| SIM card | Built-in; cellular data included, no network fee |
Source: Aethair PRO Technical Specifications (Rev. 3.3, September 2026).

Mounting
Choose How Aethair PRO Mounts
The mount on the back of Aethair PRO takes three interchangeable adapters, so the same monitor can go on steel, a wall, or a pole.
- Magnet Adapter: holds to steel (equipment, cabs, metal walls, and doors), or seats onto the optional round Wall Bracket.
- Wall / Locking Adapter: fits its slotted Wall Bracket and locks the monitor in place.
- Strap Adapter: takes a hose clamp around a pole, pipe, or rail.
Outdoors, Aethair PRO can run on solar power with the optional Solar Panel Bracket.
Still deciding?
The Other Aethair Devices: Aethair IAQ and Thiamis

Aethair IAQ
Compact plug-in monitor with every sensor built in, nothing to add. Ideal for straightforward indoor air quality monitoring.
13 built-in parameters: CO₂, PM2.5, PM10, tVOC and more
See Aethair IAQ

Thiamis
A gateway that connects the third-party instruments you choose to the Aethair Platform.
RS-232, RS-485, SDI-12, and USB · 224 device models from 35 integrations
See Thiamis
Standards
Monitor for These Standards with Aethair PRO
Monitor with built-in sensors:
Monitor with cartridges:
Guidance that references these measurements without setting a limit:
Article Library
Reading for Aethair PRO Deployments
Guides that put Aethair PRO to work: the programs, standards, and sites it is used for.
Ambient Air Quality Monitoring: What Nonattainment Changes
Ambient air quality monitoring explained: how PM2.5 attainment is measured, what a nonattainment designation triggers, and what site-level monitoring adds.
Ozone Exposure Limits and Monitoring: OSHA and NAAQS
OSHA's ozone PEL is 0.1 ppm as an 8-hour TWA. How NIOSH, ACGIH, and the 70 ppb NAAQS compare, and why ozone needs short-interval monitoring.
Air Quality Near Data Centers: What Communities Should Know
Air quality near data centers: construction dust, diesel generator emissions, and noise, and how communities get independent monitoring data.
Fenceline Air Quality Monitoring: Equipment and Approaches
Compare fenceline air quality monitoring approaches: standalone stations, pelican-case kits, and connected 4G sensor networks.
Data Center Air Quality Monitoring, Inside and Out
Data center air quality monitoring for operators: ISO 14644 cleanliness in the white space, construction dust, generator emissions, and perimeter noise.
Wildfire Smoke Air Quality Monitoring: Detection & Response
Wildfire smoke monitoring for EHS and public health teams: real-time PM2.5, the AQI 151 respirator trigger, and how to alert workers before smoke arrives.
Questions
Aethair PRO FAQ
How is Aethair PRO used in EHS programs?
Can it run off-grid?
What does field reconfiguration involve?
Who installs Aethair PRO?
How is Aethair PRO bought?
Put Aethair PRO on Your Site
Schedule an Aethair PRO DemoBuild a monitoring configuration Outdoor & ambient monitoring solution Case study: cabin monitoring at Drummond Gas sensor cartridge specifications Choosing between Aethair PRO, Aethair IAQ, and Thiamis
A 30-minute call: you tell us about your application, then we demo the solution for it.