South Coast Air Quality Management District Rule 1180 (most recently amended January 5, 2024) requires petroleum refineries and related facilities in the district to run real-time fenceline air monitoring under an approved Fenceline Air Monitoring Plan, publish the data on the web, and send a public notification when a pollutant exceeds its notification threshold. The thresholds, set in the rule's Table 1 and based on a 1-hour average unless noted, include SO₂ 75 ppb, H₂S 30 ppb, benzene 8 ppb, formaldehyde 44 ppb, ammonia 4,507 ppb, hydrogen fluoride 289 ppb, PM2.5 35 µg/m³ and PM10 50 µg/m³ (24-hour), and an information-based 730 ppb for total VOCs as non-methane hydrocarbons.

Schedule a callConfigure SCAQMD 1180 Monitoring

The standard

What Rule 1180 Is

The table also lists oxides of nitrogen (100 ppb), toluene (1,300 ppb), xylenes (5,000 ppb), 1,3-butadiene, acrolein, acetaldehyde, styrene, manganese, nickel, carbonyl sulfide, and hydrogen cyanide, and names further pollutants to be addressed without a numeric threshold.

Limit values

SCAQMD 1180 Limit Values

Every value South Coast Air Quality Management District publishes for the 9 parameters below, with its averaging period, as the standard states it.

Sulfur Dioxide (SO₂) Gases & VOCs
75 ppb 1-hour, notification threshold
Hydrogen Sulfide (H₂S) Gases & VOCs
30 ppb 1-hour, notification threshold
BTEX / speciated VOC Gases & VOCs
8 ppb 1-hour, notification thresholdbenzene; toluene 1,300 ppb and xylenes 5,000 ppb
Formaldehyde (CH₂O) Gases & VOCs
44 ppb 1-hour, notification threshold
Ammonia (NH₃) Gases & VOCs
4507 ppb 1-hour, notification threshold
Hydrogen Fluoride (HF) Gases & VOCs
289 ppb 1-hour, notification threshold
VOC (Total) Gases & VOCs
730 ppb 1-hour, information-based thresholdtotal VOCs as non-methane hydrocarbons
PM2.5 Particulate Matter
35 µg/m³ 24-hour, notification threshold
PM10 Particulate Matter
50 µg/m³ 24-hour, notification threshold

Who it applies to

Who It Applies to

Petroleum refineries and specified related facilities in the South Coast district (Los Angeles, Orange, and parts of Riverside and San Bernardino counties). Each operator installs and runs the fenceline system described in its plan, and refineries also fund community air monitoring nearby.

Monitoring

How Monitoring Demonstrates Compliance

Rule 1180 is a continuous monitoring rule. Open-path and point instruments along the fence report in real time, and the notification program automatically compares their readings with the Table 1 thresholds, issuing follow-up notices while an exceedance lasts. The record that matters is the time series, its completeness, and the notifications sent. Wind direction alongside each reading is what lets the facility and the public tell a fenceline release from a passing regional plume.

Recommended

best match
9 of 9 covered · 1 monitor · 1 gateway · 2 instruments
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Built-inPM10PM2.5

    Gas 1

    Aethair VOC (ppm PID)

    VOC (Total)

    A 10.6 eV photoionization detector (PID) ionizes volatile organic compounds for direct ppm readings across a…

    Also fits: Aethair VOC (ppb PID), Aethair MultiGas+, Aethair VOC (ppb PID, wide range)

    Gas 2

    Aethair H₂S

    Hydrogen Sulfide (H₂S)

    Filtered four-electrode electrochemical sensing resolves H₂S to parts per billion, for wastewater, odor, oil…

    MultiSense

    Custom MultiSense built to order

    Sulfur Dioxide (SO₂)Formaldehyde (CH₂O)Hydrogen Fluoride (HF)

    Built to order for the MultiSense socket with the Aethair SO₂ cartridge's sensor (0-100 ppm, 5 ppb resolution), the Aethair MultiSense cartridge's sensor (0-10 ppm, 10 ppb resolution), and the Aethair HF cartridge's sensor (0-10 ppm, 0.05 ppm resolution).

    Expansion

    Free: differential pressure

    Also measures 11 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature
  2. Thiamis connects 2 instruments

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • Defiant Technologies Specialty Air Analyzers

      BTEX / speciated VOC

      Defiant Technologies FROG portable gas chromatograph (GC-PID).

      Connects over USB (ASCII)

    • RAE Gas Detectors

      Ammonia (NH₃)

      RAE Systems (Honeywell) portable gas detectors.

      Models with Ammonia (NH₃): MultiRAE Lite, MultiRAE, MultiRAE Pro, MultiRAE Plus and 2 more · Connects over RS-232 (ASCII)

    Also measures 8 more
    Methane (CH₄)Chlorine (Cl₂)Carbon Monoxide (CO)Carbon Dioxide (CO₂)Combustible (LEL)Nitric Oxide (NO)Nitrogen Dioxide (NO₂)Oxygen (O₂)

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Sulfur Dioxide (SO₂)MultiSense, SO₂ cartridges—1 instrument via Thiamis
Hydrogen Sulfide (H₂S)H₂S cartridge—4 instruments via Thiamis
BTEX / speciated VOC——1 instrument via Thiamis
Formaldehyde (CH₂O)MultiSense cartridgeBuilt in—
Ammonia (NH₃)——1 instrument via Thiamis
Hydrogen Fluoride (HF)HF cartridge——
VOC (Total)VOC (ppm PID), VOC (ppb PID) +2 cartridgesBuilt in2 instruments via Thiamis
PM2.5Built inBuilt in3 instruments via Thiamis
PM10Built inBuilt in3 instruments via Thiamis

Devices

Devices That Cover SCAQMD 1180

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers part of it (combine on one Thiamis)

Solutions

Solutions Judged Against SCAQMD 1180

All solutions

Article Library

Articles on SCAQMD 1180

All articles

Questions

SCAQMD 1180 FAQ

What are the Rule 1180 notification thresholds?

Among others: SO₂ 75 ppb, H₂S 30 ppb, benzene 8 ppb, formaldehyde 44 ppb, ammonia 4,507 ppb, and hydrogen fluoride 289 ppb as 1-hour averages; PM2.5 35 µg/m³ and PM10 50 µg/m³ as 24-hour averages; and 730 ppb for total VOCs as an information-based threshold.

What happens when a Rule 1180 threshold is exceeded?

The facility's web-based notification program automatically notifies the public, giving the pollutant, the concentration measured, and the threshold, and sends follow-up notifications while the exceedance continues.

Which facilities fall under Rule 1180?

Petroleum refineries and specified related facilities in the South Coast Air Quality Management District, each under an approved Fenceline Air Monitoring Plan.