Sensors · Gas Detectors

RAE Gas Detectors

RAE Systems (Honeywell) portable gas detectors. MultiRAE platforms are multi-gas monitors with 1 to 6 sensors, including an optional PID. The miniRAE, ppbRAE, and ultraRAE are handheld PID VOC monitors covering ppm to ppb levels (the ultraRAE adds benzene-specific measurement), and the VRAE is a five-gas monitor.

Schedule a callBuild a Configuration

Measures

What RAE Gas Detectors Measure

12 parameters, each linked to its page: the sensors, units, and standards behind it.

Models

RAE Gas Detectors Models

11 models, each with what it measures and the ranges its datasheet gives.

ModelDescriptionMeasures & specs
MultiRAE LiteConfigurable 1-to-6-gas monitor (PGM-6208) with 25+ interchangeable sensors: combustible LEL, O2, toxic electrochemicals (CO, H2S, SO2, NO, NO2, NH3, Cl2), NDIR CO2, and optional PID for VOCs. Pumped or diffusion.
MultiRAESix-sensor multi-gas + PID monitor (PGM-6228). Full toxic/combustible/O2 menu plus a ppb-capable PID for VOCs and an optional NDIR CO2 channel.
MultiRAE ProFlagship MultiRAE (PGM-6248) for hazmat and emergency response: the full six-sensor multi-gas + PID panel, with the broadest sensor and wireless options of the family.
miniRAE 3000Handheld broadband PID VOC monitor (PGM-7320), 0-15,000 ppm, 10.6 eV lamp, 200+ correction factors. Measures total VOCs only. Now sold as the miniRAE 3000+.
ppbRAE 3000Handheld PID VOC monitor (PGM-7340) with ppb sensitivity (1 ppb-10,000 ppm). Total VOCs only. Now sold as the ppbRAE 3000+.
ultraRAE 3000Compound-specific handheld PID (PGM-7360): benzene mode via a pre-filter separation tube (10 ppb-200 ppm) plus a broadband VOC mode to 10,000 ppm. Reading is published as total VOC. Now sold as the ultraRAE 3000+.
MultiRAE PlusLegacy previous-generation multi-gas + PID monitor (PGM50-5P): LEL, O2, and toxic gases (CO, H2S, SO2, NO, NO2, NH3, Cl2) with an optional PID; no NDIR CO2. Superseded by the current MultiRAE.
MultiRAE IRLegacy MultiRAE variant (PGM54) adding an NDIR CO2 channel to the multi-gas + PID panel. Superseded by the current MultiRAE.
ppbRAE 2000Legacy ppb-level PID VOC monitor (PGM7240); total VOCs only. Predecessor to the ppbRAE 3000.
miniRAE 2000Legacy broadband PID VOC monitor (PGM7600); total VOCs only. Predecessor to the miniRAE 3000.
VRAELegacy pumped 1-to-5-gas monitor (PGM-7800/7840): combustible (LEL) + O2 + up to four toxic sensors (CO, H2S, SO2, NO, NO2, NH3, Cl2). No NDIR CO2; discontinued.

Standards

Standards for What It Measures

Standards that set limits on the parameters it reports.

Solutions

Where RAE Gas Detectors Are Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

On the platform

What RAE Gas Detectors Get From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

Similar

Other Gas Detectors

Article Library

Reading on What These Instruments Measure

All articles

Questions

RAE Gas Detectors FAQ

Which RAE models measure a full gas panel, and which measure only VOCs?

The MultiRAE family (MultiRAE Lite, MultiRAE, MultiRAE Pro) and the legacy VRAE, MultiRAE Plus, and MultiRAE IR are configurable multi-gas instruments, and the integration reads whatever sensors are installed. The miniRAE, ppbRAE, and ultraRAE handhelds are single-detector PID monitors: they report total VOCs only, plus peak, low, STEL, and TWA statistics of that VOC reading.

How does the integration know which gases a MultiRAE is fitted with?

On each poll the driver issues an 'N' command that returns the list of installed sensor names (for example 'SO2 NO2 H2S CO VOC'), then reads their values in that order with the 'R' command. As a result, a MultiRAE or VRAE publishes exactly the sensors physically installed; the panel is not fixed in firmware. The single-detector PID handhelds skip this step and read one VOC value directly.

What does the ultraRAE 3000 measure - benzene or VOCs?

The ultraRAE 3000 is a compound-specific PID: in benzene mode a pre-filter separation tube isolates benzene (about 10 ppb-200 ppm), and it also has a broadband VOC mode to 10,000 ppm. The integration publishes the reading as total VOC.

Why does a VRAE or MultiRAE Plus show a VOC reading even without a PID?

The firmware maps several specialty electrochemical channels (hydrogen cyanide (HCN), phosphine (PH3), and ethylene oxide (EtO)), plus the combustible-by-volume (VOL) channel, onto the total-VOC parameter, because Aethair has no separate parameter for them. So a unit fitted with an HCN or PH3 sensor reports under VOC.

Are the 2000-series handhelds, MultiRAE Plus/IR, and VRAE still sold?

No. The 2000-series PID handhelds (miniRAE 2000, ppbRAE 2000), the previous-generation MultiRAE Plus and MultiRAE IR, and the VRAE five-gas monitor are discontinued; the current 3000-series handhelds are now sold as the '3000+'. They remain in the driver for installed-base support.

Sources: sps-support.honeywell.com · automation.honeywell.com · automation.honeywell.com

Bring the RAE Gas Detectors Into Environet

Schedule a callBuild a Configuration All sensors How Thiamis connects it

A 30-minute call: you tell us about your application, then we demo the solution for it.