Cal/OSHA Permissible Exposure Limits (8 CCR §5155, Table AC-1)
Occupational: legal limit (California), 8-hour TWA unless noted
California sets its own workplace exposure limits in 8 CCR §5155, Airborne Contaminants, whose Table AC-1 lists a permissible exposure limit (8-hour TWA), a short-term exposure limit (15-minute), and a ceiling for each regulated substance. Cal/OSHA has updated its table far more recently than federal OSHA, so many values are stricter. Examples include carbon monoxide at 25 ppm with a 200 ppm ceiling (federal: 50 ppm); ozone at 0.1 ppm with a 0.3 ppm STEL; sulfur dioxide at 2 ppm with a 5 ppm STEL; hydrogen sulfide at 10 ppm with a 15 ppm STEL and a 50 ppm ceiling; and nitrogen dioxide with a 1 ppm STEL.
Limit values
Cal/OSHA PEL Limit Values
Every value Cal/OSHA publishes for the 13 parameters below, with its averaging period, as the standard states it.
Who it applies to
Who Must Comply
Employers in California. Where Cal/OSHA's limit is stricter than the federal PEL, the California value applies; OSHA's annotated PEL tables reproduce the Cal/OSHA values alongside the federal ones for comparison.
Monitoring
How Monitoring Demonstrates Compliance
Each limit is compared with exposure over its own period: the 8-hour TWA for the PEL, 15 minutes for the STEL, any moment for a ceiling. Continuous monitoring is what shows a STEL or ceiling being approached, which a shift-average sample cannot; personal sampling in the breathing zone documents individual exposure.
Recommended
best match-
Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.
Gas 1
Aethair O₃+NO₂
Nitrogen Dioxide (NO₂)Ozone (O₃)Four-electrode electrochemical sensing measures oxidizing gases (ozone plus nitrogen dioxide) and reports one…
Gas 2
Aethair CO (electrochemical)
Carbon Monoxide (CO)An amperometric electrochemical CO cell with a solid, non-aqueous electrolyte (the long-life, low-power…
Also fits: Aethair MultiGas+, Aethair CO (ppb, four-electrode)
MultiSense
Custom MultiSense built to order
Carbon Dioxide (CO₂)Hydrogen Sulfide (H₂S)Sulfur Dioxide (SO₂)Built to order for the MultiSense socket with the Aethair CO₂ (dual NDIR) cartridge's sensor (0-5000 ppm, 1 ppm resolution), the Aethair H₂S cartridge's sensor (0-50 ppm, 5 ppb resolution), and the Aethair SO₂ cartridge's sensor (0-100 ppm, 5 ppb resolution).
Expansion
Free: differential pressure
Also measures 13 more
Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature -
Thiamis connects 3 instruments
A gateway that connects the third-party instruments you choose to the Aethair Platform.
-
Chlorine (Cl₂)Ammonia (NH₃)Nitric Oxide (NO)
RAE Systems (Honeywell) portable gas detectors.
-
Defiant Technologies Specialty Air Analyzers
BTEX / speciated VOCDefiant Technologies FROG portable gas chromatograph (GC-PID).
-
AMETEK Brookfield Specialty Air Analyzers
Mercury (Hg)Jerome portable single-gas analyzers by AMETEK Brookfield (formerly AMETEK Arizona Instrument).
Also measures 4 more
Methane (CH₄)Combustible (LEL)Oxygen (O₂)VOC (Total) -
Not coveredHydrogen Chloride (HCl)Hydrogen Fluoride (HF)no supported configuration measures these yet
Who measures each parameter
| Parameter | |||
|---|---|---|---|
| Carbon Monoxide (CO) | CO (electrochemical), MultiGas+ +1 cartridges | — | 3 instruments via Thiamis |
| Carbon Dioxide (CO₂) | CO₂ (dual NDIR), CO₂ (self-calibrating NDIR) cartridges | Built in | 2 instruments via Thiamis |
| Hydrogen Sulfide (H₂S) | H₂S cartridge | — | 4 instruments via Thiamis |
| Sulfur Dioxide (SO₂) | MultiSense, SO₂ cartridges | — | 1 instrument via Thiamis |
| Nitric Oxide (NO) | NO cartridge | — | 1 instrument via Thiamis |
| Nitrogen Dioxide (NO₂) | NO₂, MultiSense +1 cartridges | — | 1 instrument via Thiamis |
| Ozone (O₃) | O₃+NO₂ cartridge | — | 1 instrument via Thiamis |
| Ammonia (NH₃) | — | — | 1 instrument via Thiamis |
| Chlorine (Cl₂) | — | — | 1 instrument via Thiamis |
| Mercury (Hg) | — | — | 1 instrument via Thiamis |
| Hydrogen Chloride (HCl) | HCl cartridge | — | — |
| Hydrogen Fluoride (HF) | HF cartridge | — | — |
| BTEX / speciated VOC | — | — | 1 instrument via Thiamis |
Devices
Devices That Cover Cal/OSHA PEL
How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.
Aethair monitors
Covers part of it (combine on one Thiamis)
Solutions
Solutions Judged Against Cal/OSHA PEL
Occupational Safety & Industrial Hygiene
Worker exposure, confined space, and heat stress
Article Library
Articles on Cal/OSHA PEL
Ozone Exposure Limits and Monitoring: OSHA and NAAQS
OSHA's ozone PEL is 0.1 ppm as an 8-hour TWA. How NIOSH, ACGIH, and the 70 ppb NAAQS compare, and why ozone needs short-interval monitoring.
Questions
Cal/OSHA PEL FAQ
What is the Cal/OSHA PEL for carbon monoxide?
25 ppm as an 8-hour time-weighted average, with a ceiling of 200 ppm, stricter than the federal OSHA PEL of 50 ppm.
What does Cal/OSHA set for ozone?
A permissible exposure limit of 0.1 ppm as an 8-hour TWA and a short-term exposure limit of 0.3 ppm.
Which limit applies in California, federal or Cal/OSHA?
California employers follow Cal/OSHA's Table AC-1, which is stricter than the federal limits for many substances.
Monitor Against Cal/OSHA PEL
Schedule a callBuild a Configuration All standards