Compliance · ISO

ISO 23875: air quality control systems for operator enclosures

Occupational: operator enclosures of mining and heavy machines

ISO 23875:2021 (amended in 2022), Mining — Air quality control systems for operator enclosures, sets performance requirements for the cabs of mining machines and the systems that keep their air clean. Clause 4.1 sets three requirements. Sustained cab CO₂ must stay no more than 400 ppm above ambient (a measure of ventilation). Respirable particulate must be 25 µg/m³ or less at the start and end of the standard's decay test, with a decay time of 120 seconds at most. Cab pressurization must hold between 20 Pa and 200 Pa with the machine's electrical system on. It also requires an operator notification system for CO₂.

Schedule a callConfigure ISO 23875 Monitoring

The standard

What ISO 23875 Is

The 25 µg/m³ figure is a test criterion rather than a standing in-cab limit. Gases and vapors outside the cab fall beyond the standard's scope.

Limit values

ISO 23875 Limit Values

Every value ISO publishes for the 3 parameters below, with its averaging period, as the standard states it.

Carbon Dioxide (CO₂) Gases & VOCs
400 ppm Sustained, above ambientcab CO₂ no more than 400 ppm above ambient (clause 4.1)
PM4 (Respirable) Particulate Matter
25 µg/m³ Decay test, start and endrespirable particulate; decay time 120 s at most
Differential Pressure Meteorology
20 Pa Minimum, sustainedcab pressurization with the machine's electrical system on
200 Pa Maximumcab pressurization

Who it applies to

Who Uses It

Mine operators and machine manufacturers specifying and verifying cab air quality control systems. It was written by ISO's mining committee, but its design and test requirements are written to be universal, for fixed and mobile operator enclosures alike. A revision is in preparation at ISO.

Monitoring

How Monitoring Supports It

The requirements are measured inside the cab: CO₂ against the ambient level, cab pressure, and particulate during testing and in service. A monitor in each cab that records CO₂, differential pressure, and particulate continuously shows whether filtration and pressurization hold while the machine works, and flags a loaded filter or a failed seal across a fleet.

Recommended

best match
3 of 3 covered · 1 monitor · 1 gateway · 1 instrument
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Gas 1

    Aethair CO₂ (dual NDIR)

    Carbon Dioxide (CO₂)

    Dual-thermopile NDIR (non-dispersive infrared) sensing measures CO₂ with no chemical consumables, for…

    Also fits: Aethair CO₂ (self-calibrating NDIR)

    Gas 2

    Free: one more gas sensor cartridge

    MultiSense

    Free: a MultiSense, stock or built to order

    Expansion

    Aethair Diff. Pressure

    Differential Pressure

    A gauge sensor reads 0–10 kPa, with the higher-pressure side connected to its port.

    Also measures 13 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature
  2. Thiamis connects 1 instrument

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • TSI Particulate & Dust Monitors

      PM4 (Respirable)

      TSI DustTrak real-time light-scattering laser photometers for aerosol/dust mass-concentration monitoring.

      Models with PM4 (Respirable): DustTrak 8533, DustTrak 8533EP, DustTrak 8534, DustTrak 8543 and 1 more · Connects over RS-232 (ASCII)

      Swap for

    Also measures 4 more
    PM1PM10PM2.5Total PM / Mass Conc.

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Carbon Dioxide (CO₂)CO₂ (dual NDIR), CO₂ (self-calibrating NDIR) cartridgesBuilt in2 instruments via Thiamis
PM4 (Respirable)——2 instruments via Thiamis
Differential PressureDiff. Pressure cartridge——

Devices

Devices That Cover ISO 23875

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers part of it (combine on one Thiamis)

Solutions

Solutions Judged Against ISO 23875

All solutions

Questions

ISO 23875 FAQ

What does ISO 23875 require for cab air?

Sustained cab CO₂ no more than 400 ppm above ambient, respirable particulate of 25 µg/m³ or less at the start and end of the decay test (with a decay time of 120 seconds at most), and sustained pressurization between 20 Pa and 200 Pa.

Is 25 µg/m³ a limit for the air in the cab?

No. It is the particulate level at the start and end of the standard's decay test, not a standing limit for cab air during operation.

Does ISO 23875 cover gases such as CO?

No. Gases and vapors outside the cab fall beyond its scope, so a mine monitors them under its own rules.