Compliance · New York State Department of Environmental Conservation
NYSDEC DER-10 Community Air Monitoring Plan (CAMP)
Ambient air: remediation site perimeter (New York)
DER-10 is the New York State Department of Environmental Conservation's Technical Guidance for Site Investigation and Remediation (May 2010), and its Appendix 1A is the New York State Department of Health's generic Community Air Monitoring Plan (CAMP). It sets real-time action levels at the perimeter of the work area. For dust, a downwind PM10 level more than 100 µg/m³ above upwind over 15 minutes calls for suppression, and work stops if it stays more than 150 µg/m³ above upwind after suppression. For vapors, total organic vapors more than 5 ppm above background as a 15-minute average halt work, and activities shut down above 25 ppm at the perimeter.
The standard
What the DER-10 Community Air Monitoring Plan Is
Appendix 1B adds a fugitive dust and particulate monitoring program, including the minimum performance of the real-time PM10 monitors: a measurement range of 0.001 to 400 mg/m³, accuracy of ±5 % of reading plus precision against a gravimetric calibration, alarms averaged over real time or 15 minutes, and logged data with time and date.
Limit values
NYSDEC DER-10 Limit Values
Every value New York State Department of Environmental Conservation publishes for the 2 parameters below, with its averaging period, as the standard states it.
Who it applies to
Who It Applies to
The CAMP applies to intrusive work at remediation sites in New York overseen by the Department (investigation and cleanup under the state's remedial programs, brownfield cleanups among them), wherever ground disturbance could release contaminated dust or vapors toward people living or working nearby. Monitoring runs at the upwind and downwind perimeter of the exclusion zone throughout the intrusive work, and all 15-minute readings must be recorded and available to the Department and the Department of Health.
Monitoring
How Monitoring Demonstrates Compliance
The plan is written around real-time instruments: a PM10 monitor at the upwind and at the downwind perimeter, each integrating over 15 minutes or less with an audible alarm, and an organic vapor monitor calibrated daily that calculates 15-minute running averages. Compliance is shown by the record: every 15-minute average, the upwind background it was compared with, and what was done when a level was exceeded. Wind data makes the upwind/downwind comparison defensible, because the stations have to be where the wind actually puts them. The configurator assembles a boundary node for PM10, VOCs, and wind.
Recommended
best match-
Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.
Built-inPM10Gas 1
Aethair VOC (ppm PID)
VOC (Total)A 10.6 eV photoionization detector (PID) ionizes volatile organic compounds for direct ppm readings across a…
Also fits: Aethair VOC (ppb PID), Aethair MultiGas+, Aethair VOC (ppb PID, wide range)
Gas 2
Free: one more gas sensor cartridge
MultiSense
Free: a MultiSense, stock or built to order
Expansion
Free: differential pressure
Also measures 12 more
Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature
Recommended
best match-
Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.
Built-inPM10Gas 1
Aethair VOC (ppm PID)
VOC (Total)A 10.6 eV photoionization detector (PID) ionizes volatile organic compounds for direct ppm readings across a…
Also fits: Aethair VOC (ppb PID), Aethair MultiGas+, Aethair VOC (ppb PID, wide range)
Gas 2
Free: one more gas sensor cartridge
MultiSense
Free: a MultiSense, stock or built to order
Expansion
Free: differential pressure
Also measures 12 more
Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature -
Thiamis connects 1 instrument
A gateway that connects the third-party instruments you choose to the Aethair Platform.
-
Wind DirectionWind Speed
R.M. Young ResponseONE weather instruments, with solid-state ultrasonic wind sensing and no moving parts.
Swap for
Also measures 3 more
Relative HumidityBarometric PressureAir Temperature -
Who measures each parameter
| Parameter | |||
|---|---|---|---|
| PM10 | Built in | Built in | 3 instruments via Thiamis |
| VOC (Total) | VOC (ppm PID), VOC (ppb PID) +2 cartridges | Built in | 2 instruments via Thiamis |
Devices
Devices That Cover NYSDEC DER-10
How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.
Aethair monitors
Covers part of it (combine on one Thiamis)
Solutions
Solutions Judged Against NYSDEC DER-10
Perimeter Monitoring
Site boundary dust, silica, and noise compliance
Article Library
Articles on NYSDEC DER-10
Industrial Perimeter Air Quality Monitoring: Action Levels
What industrial perimeter monitoring requires at fenceline and construction sites: DER-10 CAMP action levels, EPA fenceline rules, and continuous records.
How to Choose an Air Quality Monitor: PRO, IAQ, or Thiamis
Compare Aethair PRO, IAQ, and Thiamis to match the right device to your site, from commercial interiors to industrial and fenceline monitoring.
Questions
NYSDEC DER-10 FAQ
What are the DER-10 dust action levels?
A downwind PM10 level more than 100 µg/m³ above the upwind level over 15 minutes requires dust suppression, and work must stop if, after suppression, the downwind level stays more than 150 µg/m³ above upwind.
What are the DER-10 VOC action levels?
Total organic vapors more than 5 ppm above background as a 15-minute average at the downwind perimeter halt work until readings drop back. If levels persist between 5 and 25 ppm, the source must be found and corrected. Above 25 ppm at the perimeter, activities are shut down.
What kind of monitor does DER-10 require for particulates?
A real-time monitor for particulate matter under 10 micrometers that integrates over 15 minutes or less and has an audible alarm. Appendix 1B sets minimum performance, including a range of 0.001 to 400 mg/m³ and accuracy of ±5 % of reading plus precision.
Monitor Against NYSDEC DER-10
Schedule a callBuild a Configuration All standards
A 30-minute call: you tell us about your application, then we demo the solution for it.