Compliance · US NIOSH (CDC)

NIOSH Recommended Exposure Limits (RELs)

Occupational: recommended guideline (USA), up to 10-hour TWA unless noted

The US National Institute for Occupational Safety and Health (NIOSH), part of the CDC, publishes Recommended Exposure Limits (RELs) in its Pocket Guide to Chemical Hazards: time-weighted averages for up to a 10-hour workday, short-term limits (STEL, usually 15 minutes), and ceilings. They are health-based recommendations rather than enforceable law, and they are often stricter than the OSHA PELs set decades ago. Examples include carbon monoxide at 35 ppm TWA with a 200 ppm ceiling (OSHA: 50 ppm), hydrogen sulfide at a 10 ppm ceiling over 10 minutes, nitrogen dioxide at 1 ppm STEL, ozone at a 0.1 ppm ceiling, and the carcinogens formaldehyde and benzene at 0.016 ppm and 0.1 ppm TWA.

Schedule a callConfigure NIOSH REL Monitoring

The standard

What the NIOSH Recommended Exposure Limits Are

The Pocket Guide also lists IDLH values (concentrations immediately dangerous to life or health, such as 1,200 ppm for carbon monoxide), which are respirator-selection criteria, not exposure limits.

Limit values

NIOSH REL Limit Values

Every value US NIOSH (CDC) publishes for the 14 parameters below, with its averaging period, as the standard states it.

Carbon Monoxide (CO) Gases & VOCs
35 ppm TWA
200 ppm Ceiling
Carbon Dioxide (CO₂) Gases & VOCs
5000 ppm TWA
30000 ppm STEL
Hydrogen Sulfide (H₂S) Gases & VOCs
10 ppm Ceiling10-minute
Ozone (O₃) Gases & VOCs
0.1 ppm Ceiling
Ammonia (NH₃) Gases & VOCs
25 ppm TWA
35 ppm STEL
Chlorine (Cl₂) Gases & VOCs
0.5 ppm Ceiling15-minute
Mercury (Hg) Gases & VOCs
0.05 mg/m³ TWAmercury vapor; skin
Formaldehyde (CH₂O) Gases & VOCs
0.016 ppm TWAcarcinogen
0.1 ppm Ceiling15-minute
Hydrogen Fluoride (HF) Gases & VOCs
3 ppm TWA
6 ppm Ceiling15-minute
BTEX / speciated VOC Gases & VOCs
0.1 ppm TWAbenzene; carcinogen
1 ppm STELbenzene

Who it applies to

Who Uses Them

Industrial hygienists and employers who want a more protective benchmark than the legal minimum, and anyone comparing OSHA's limits with current science. OSHA's annotated PEL tables list them beside the enforceable limits, and many company exposure programs and gas-detector alarm setpoints are built on them, such as the 35 ppm carbon monoxide alarm common on portable detectors.

Monitoring

How Monitoring Supports Them

A REL is compared with a measured exposure over its own period: a shift TWA, a 15-minute STEL, or, for a ceiling, any moment. Continuous monitoring is what catches ceilings and short-term peaks that a shift-average sample smooths away: an ozone ceiling breached during each weld, a hydrogen sulfide spike when a hatch opens. Personal sampling in the breathing zone remains the reference for individual exposure; fixed monitors document the area.

Recommended

best match
12 of 14 covered · 2 monitors · 1 gateway · 3 instruments
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Gas 1

    Aethair O₃+NO₂

    Nitrogen Dioxide (NO₂)Ozone (O₃)

    Four-electrode electrochemical sensing measures oxidizing gases (ozone plus nitrogen dioxide) and reports one…

    Gas 2

    Aethair CO (electrochemical)

    Carbon Monoxide (CO)

    An amperometric electrochemical CO cell with a solid, non-aqueous electrolyte (the long-life, low-power…

    Also fits: Aethair MultiGas+, Aethair CO (ppb, four-electrode)

    MultiSense

    Custom MultiSense built to order

    Carbon Dioxide (CO₂)Hydrogen Sulfide (H₂S)Sulfur Dioxide (SO₂)

    Built to order for the MultiSense socket with the Aethair CO₂ (dual NDIR) cartridge's sensor (0-5000 ppm, 1 ppm resolution), the Aethair H₂S cartridge's sensor (0-50 ppm, 5 ppb resolution), and the Aethair SO₂ cartridge's sensor (0-100 ppm, 5 ppb resolution).

    Expansion

    Free: differential pressure

    Also measures 13 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature
  2. Aethair IAQ built-in sensors

    Compact plug-in monitor with every sensor built in, nothing to add. Ideal for straightforward indoor air quality monitoring.

    Built-inFormaldehyde (CH₂O)
    Also measures 11 more
    Dew PointHeat IndexRelative HumidityParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureAir TemperatureVOC (Total)
  3. Thiamis connects 3 instruments

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • RAE Gas Detectors

      Chlorine (Cl₂)Ammonia (NH₃)Nitric Oxide (NO)

      RAE Systems (Honeywell) portable gas detectors.

      Models covering all of it: MultiRAE Lite, MultiRAE, MultiRAE Pro, MultiRAE Plus and 2 more · Connects over RS-232 (ASCII)

    • Defiant Technologies Specialty Air Analyzers

      BTEX / speciated VOC

      Defiant Technologies FROG portable gas chromatograph (GC-PID).

      Connects over USB (ASCII)

    • AMETEK Brookfield Specialty Air Analyzers

      Mercury (Hg)

      Jerome portable single-gas analyzers by AMETEK Brookfield (formerly AMETEK Arizona Instrument).

      Model with Mercury (Hg): Jerome-431X · Connects over RS-232 (ASCII)

    Also measures 4 more
    Methane (CH₄)Combustible (LEL)Oxygen (O₂)VOC (Total)

Not coveredHydrogen Chloride (HCl)Hydrogen Fluoride (HF)no supported configuration measures these yet

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Carbon Monoxide (CO)CO (electrochemical), MultiGas+ +1 cartridges—3 instruments via Thiamis
Carbon Dioxide (CO₂)CO₂ (dual NDIR), CO₂ (self-calibrating NDIR) cartridgesBuilt in2 instruments via Thiamis
Hydrogen Sulfide (H₂S)H₂S cartridge—4 instruments via Thiamis
Sulfur Dioxide (SO₂)MultiSense, SO₂ cartridges—1 instrument via Thiamis
Nitric Oxide (NO)NO cartridge—1 instrument via Thiamis
Nitrogen Dioxide (NO₂)NO₂, MultiSense +1 cartridges—1 instrument via Thiamis
Ozone (O₃)O₃+NO₂ cartridge—1 instrument via Thiamis
Ammonia (NH₃)——1 instrument via Thiamis
Chlorine (Cl₂)——1 instrument via Thiamis
Mercury (Hg)——1 instrument via Thiamis
Formaldehyde (CH₂O)MultiSense cartridgeBuilt in—
Hydrogen Chloride (HCl)HCl cartridge——
Hydrogen Fluoride (HF)HF cartridge——
BTEX / speciated VOC——1 instrument via Thiamis

Devices

Devices That Cover NIOSH REL

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers part of it (combine on one Thiamis)

Solutions

Solutions Judged Against NIOSH REL

All solutions

Article Library

Articles on NIOSH REL

All articles

Questions

NIOSH REL FAQ

What is the NIOSH REL for carbon monoxide?

35 ppm as a time-weighted average, with a ceiling of 200 ppm, compared with OSHA's permissible exposure limit of 50 ppm.

Are NIOSH RELs enforceable?

No. They are health-based recommendations. OSHA's permissible exposure limits are the enforceable federal limits; the RELs are often stricter and are widely used as internal limits and alarm setpoints.

What is the difference between a REL and an IDLH value?

A REL is an exposure limit for workers over a stated period. An IDLH value is the concentration immediately dangerous to life or health, used to select respirators, not as an exposure limit.