EPA Landfill Explosive Gases Control (40 CFR 258.23)

Ambient air: methane migration at municipal solid waste landfills (USA)

The US EPA's criteria for municipal solid waste landfills include an explosive gases control standard, 40 CFR 258.23. Owners and operators must ensure that the methane generated by the landfill does not exceed 25 % of the lower explosive limit (LEL) in facility structures (excluding gas control or recovery components) and does not exceed the lower explosive limit at the facility property boundary. They must run a routine methane monitoring program, at least quarterly.

Schedule a callConfigure EPA 258.23 Monitoring

Limit values

EPA 258.23 Limit Values

Every value US EPA publishes for the parameter below, with its averaging period, as the standard states it.

Methane (CH₄) Gases & VOCs
25 %LEL In facility structuresexcluding gas control or recovery components
100 %LEL At the property boundarythe lower explosive limit itself

Who it applies to

Who Must Comply

Owners and operators of municipal solid waste landfill units in the United States, under state programs that implement Part 258. Landfill gas emissions to air are covered separately by the Clean Air Act landfill rules, whose surface emission monitoring uses a methane level of 500 ppm above background.

Monitoring

How Monitoring Demonstrates Compliance

The type and frequency of monitoring follow the site's soil, hydrogeologic, and hydraulic conditions and where its structures and boundary lie. If methane above the limits is detected, the operator must immediately protect human health and notify the State Director, record the levels and steps within seven days, and implement a remediation plan within 60 days. Continuous methane monitoring in structures and at boundary probes turns the quarterly minimum into a live warning.

Recommended

best match
1 of 1 covered · 1 monitor
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Gas 1

    Aethair CH₄

    Methane (CH₄)

    Molecular Property Spectrometer (MPS) MEMS sensing, poison-immune and factory-calibrated for life, for…

    Also fits: Aethair MultiGas+

    Gas 2

    Free: one more gas sensor cartridge

    MultiSense

    Free: a MultiSense, stock or built to order

    Expansion

    Free: differential pressure

    Also measures 13 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Methane (CH₄)CH₄, MultiGas+ cartridges—3 instruments via Thiamis

Devices

Devices That Cover EPA 258.23

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers it on its own

Solutions

Solutions Judged Against EPA 258.23

All solutions

Questions

EPA 258.23 FAQ

What are the landfill methane limits under 40 CFR 258.23?

Methane may not exceed 25 % of the lower explosive limit in facility structures, or the lower explosive limit at the property boundary.

How often must landfill methane be monitored?

At least quarterly, with the type and frequency set by the site's soil and hydrogeologic conditions and the location of structures and the boundary.

What must an operator do if methane exceeds the limits?

Immediately protect human health and notify the State Director, record the levels and steps taken within seven days, and implement a remediation plan within 60 days.

Monitor Against EPA 258.23

Schedule a callBuild a Configuration All standards

A 30-minute call: you tell us about your application, then we demo the solution for it.