Guidance · Bay Area Air Quality Management District

BAAQMD Regulation 12, Rule 15: petroleum refining emissions tracking

Ambient air: refinery fenceline monitoring (Bay Area, California)

Bay Area Air Quality Management District Regulation 12, Rule 15 (Petroleum Refining Emissions Tracking, adopted 2016) requires Bay Area refineries to report annual emissions inventories and crude slate information, and to run real-time fenceline air monitoring with the data made public. It sets no concentration limit. Its Air Monitoring Guidelines require refineries to measure benzene, toluene, ethylbenzene, and xylenes (BTEX) and hydrogen sulfide at the fenceline, using open-path technology that measures in the parts-per-billion range. Refineries must also consider sulfur dioxide, alkanes or other organic compound indicators, 1,3-butadiene, and ammonia, and give a rationale for any compound they leave out.

Schedule a callConfigure BAAQMD 12-15 Monitoring

Who it applies to

Who It Applies to

Petroleum refineries in the Bay Area Air Quality Management District, each under an Air Monitoring Plan the District approves. The rule has been amended since adoption, and a further amendment was under development in 2026.

Monitoring

How Monitoring Demonstrates Compliance

The guidelines ask for data at a five-minute time resolution, displayed to the public. Quality assurance is set in each refinery's plan and includes at least 75 % hourly data completeness for 90 % of the time, assessed quarterly. Because the rule sets no limit, what it asks of monitoring is coverage and continuity: the right compounds, a complete record, and siting that represents the fenceline and the community downwind.

Recommended

best match
4 of 4 covered · 1 gateway · 2 instruments
  1. Thiamis connects 2 instruments

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • RAE Gas Detectors

      Hydrogen Sulfide (H₂S)Ammonia (NH₃)Sulfur Dioxide (SO₂)

      RAE Systems (Honeywell) portable gas detectors.

      Models covering all of it: MultiRAE Lite, MultiRAE, MultiRAE Pro, MultiRAE Plus and 2 more · Connects over RS-232 (ASCII)

    • Defiant Technologies Specialty Air Analyzers

      BTEX / speciated VOC

      Defiant Technologies FROG portable gas chromatograph (GC-PID).

      Connects over USB (ASCII)

    Also measures 9 more
    Methane (CH₄)Chlorine (Cl₂)Carbon Monoxide (CO)Carbon Dioxide (CO₂)Combustible (LEL)Nitric Oxide (NO)Nitrogen Dioxide (NO₂)Oxygen (O₂)VOC (Total)

Recommended

best match
6 of 6 covered · 1 gateway · 3 instruments
  1. Thiamis connects 3 instruments

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • RAE Gas Detectors

      Hydrogen Sulfide (H₂S)Ammonia (NH₃)Sulfur Dioxide (SO₂)

      RAE Systems (Honeywell) portable gas detectors.

      Models covering all of it: MultiRAE Lite, MultiRAE, MultiRAE Pro, MultiRAE Plus and 2 more · Connects over RS-232 (ASCII)

    • R.M. Young Weather Stations

      Wind DirectionWind Speed

      R.M. Young ResponseONE weather instruments, with solid-state ultrasonic wind sensing and no moving parts.

      Connects over SDI-12

      Swap for

    • Defiant Technologies Specialty Air Analyzers

      BTEX / speciated VOC

      Defiant Technologies FROG portable gas chromatograph (GC-PID).

      Connects over USB (ASCII)

    Also measures 12 more
    Methane (CH₄)Chlorine (Cl₂)Carbon Monoxide (CO)Carbon Dioxide (CO₂)Combustible (LEL)Nitric Oxide (NO)Nitrogen Dioxide (NO₂)Oxygen (O₂)VOC (Total)Relative HumidityBarometric PressureAir Temperature

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
BTEX / speciated VOC——1 instrument via Thiamis
Hydrogen Sulfide (H₂S)H₂S cartridge—4 instruments via Thiamis
Sulfur Dioxide (SO₂)MultiSense, SO₂ cartridges—1 instrument via Thiamis
Ammonia (NH₃)——1 instrument via Thiamis

Devices

Devices That Measure What BAAQMD 12-15 Relies On

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers part of it (combine on one Thiamis)

Solutions

Solutions That Rely on BAAQMD 12-15

All solutions

Article Library

Articles on BAAQMD 12-15

All articles

Questions

BAAQMD 12-15 FAQ

Does BAAQMD Rule 12-15 set fenceline concentration limits?

No. It requires real-time fenceline monitoring and public data, not compliance with a concentration limit.

Which compounds must be monitored under Rule 12-15?

Benzene, toluene, ethylbenzene, xylenes, and hydrogen sulfide with open-path instruments measuring in the parts-per-billion range; sulfur dioxide, alkanes or other organic indicators, 1,3-butadiene, and ammonia are to be considered in each refinery's plan.

How often must Rule 12-15 fenceline data be collected?

The guidelines call for a time resolution of five minutes, with at least 75 % completeness on an hourly basis 90 % of the time, assessed by quarter.

Monitor What BAAQMD 12-15 Relies On