SCAQMD Rule 1466: particulate emissions from soils with toxic air contaminants
Ambient air: earth-moving on contaminated soil (South Coast AQMD, California)
South Coast Air Quality Management District Rule 1466 (amended June 4, 2021) controls dust from earth-moving on sites whose soil contains toxic air contaminants. It requires continuous, direct-reading PM10 monitoring upwind and downwind of the work. When the downwind minus upwind PM10 concentration exceeds 25 µg/m³ as a 120-minute rolling average, earth-moving must stop or dust controls must be applied until the level is at or below 25 µg/m³ averaged over 30 minutes.
The standard
What Rule 1466 Is
The monitors must either follow an EPA-approved equivalent method for PM10 or be approved under Rule 1466. Upwind and downwind monitors must be identical in make, model, and settings and log data at least every minute, with the precision and zero checks the rule sets out.
Limit values
SCAQMD 1466 Limit Values
Every value South Coast Air Quality Management District publishes for the parameter below, with its averaging period, as the standard states it.
Who it applies to
Who It Applies to
Owners and operators moving soil that contains toxic air contaminants of concern at a site in the South Coast district designated by the U.S. EPA as a Superfund National Priorities List site, by the California Department of Toxic Substances Control as a Brownfield or Cleanup Program site, by a state or regional water board as a Site Cleanup Program site, or by a regulatory agency as a Hazardous Material Release site. It does not apply to less than 50 cubic yards of soil or to soil removed for sampling. Wind conditions matter too: earth-moving must cease when wind speed exceeds the limit set in the rule.
Monitoring
How Monitoring Demonstrates Compliance
Compliance is the paired upwind/downwind PM10 record at one-minute resolution, the rolling 120-minute differences against 25 µg/m³, and the documentation of every stop or control measure. The rule adjusts the comparison when the wind shifts more than 90 degrees from the prevailing direction, so wind direction has to be recorded with the dust readings.
Recommended
best match-
Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.
Built-inPM10Gas 1
Free: one more gas sensor cartridge
Gas 2
Free: one more gas sensor cartridge
MultiSense
Free: a MultiSense, stock or built to order
Expansion
Free: differential pressure
Also measures 12 more
Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature
Recommended
best match-
Thiamis connects 1 instrument
A gateway that connects the third-party instruments you choose to the Aethair Platform.
-
Met One Particulate & Dust Monitors
PM10Wind DirectionWind SpeedMet One (Acoem) real-time particulate monitors.
Also measures 3 more
Relative HumidityPM2.5Air Temperature -
Who measures each parameter
| Parameter | |||
|---|---|---|---|
| PM10 | Built in | Built in | 3 instruments via Thiamis |
Devices
Devices That Cover SCAQMD 1466
How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.
Aethair monitors
Covers it on its own
Solutions
Solutions Judged Against SCAQMD 1466
Perimeter Monitoring
Site boundary dust, silica, and noise compliance
Article Library
Articles on SCAQMD 1466
Fenceline Air Quality Monitoring: Equipment and Approaches
Compare fenceline air quality monitoring approaches: standalone stations, pelican-case kits, and connected 4G sensor networks.
Questions
SCAQMD 1466 FAQ
What is the Rule 1466 PM10 threshold?
25 µg/m³, calculated as the downwind minus the upwind PM10 concentration over a 120-minute rolling average. Above it, earth-moving stops or dust controls apply until the level is at or below 25 µg/m³ averaged over 30 minutes.
What monitors does Rule 1466 require?
Continuous direct-reading PM10 monitors upwind and downwind, following an EPA-approved equivalent method or approved under the rule, identical in make, model, and settings, logging at least every minute.
Does wind matter under Rule 1466?
Yes. The rule adjusts the upwind/downwind comparison when the wind shifts more than 90 degrees from the prevailing direction, and earth-moving must cease above the wind speed it sets.