Measurements · Particulate Matter

Total PM / Mass Conc.

Also known as TSP, total suspended particulates, total dust

Total suspended particulate mass concentration across all measured sizes.

Schedule a callConfigure Total PM / Mass Conc. Monitoring

What it is

What is total particulate matter (TSP)?

Total PM (total suspended particulate, or TSP) is the whole mass of solid and liquid particles suspended in a volume of air, taken across every size fraction rather than at a single cut-point. Where PM2.5 and PM10 isolate defined size ranges, total PM aims to capture everything airborne: fine combustion particles, coarse mechanical dust, pollen, spores, sea salt, and the larger particles that settle out quickly. It is the classic "nuisance dust" or "total dust" metric, used for general dust burden, deposition complaints, and process emissions where the concern is the overall quantity of particulate rather than a specific health-defined fraction.

Because it sums all sizes, total PM is dominated by whatever coarse material a site happens to generate, which makes it a broad indicator of dustiness rather than a fine-health metric.

Health and operational effects

Most of the mass in total PM is coarse and is trapped in the nose, throat, and upper airways rather than reaching the deep lung, so on a per-microgram basis it is less hazardous than the fine fractions. It still matters, though. High total dust irritates airways, soils surfaces, reduces visibility, and generates the deposition complaints (dust on cars, sills, and laundry) that bring a site into dispute with neighbors. In the workplace, "total" or "inhalable" dust is the regulated occupational figure for many low-toxicity nuisance dusts that have no more specific limit.

For quarries, bulk-handling, agriculture, and construction, total PM at the boundary is often the nuisance and permit metric, while inhalable dust in the breathing zone is the occupational one.

How it is measured

How Total PM / Mass Conc. Is Measured

Optical (light-scattering) monitors give continuous total mass by summing the concentration across their size channels, and are the practical choice for real-time boundary and process monitoring. Gravimetric high-volume samplers are the reference method for TSP: they draw a large volume of air through a filter that is weighed before and after. A true TSP measurement depends on an inlet that admits the largest particles, and because many optical sensors are limited to around the PM10 range, their "total" reflects mass up to that inlet cut. For occupational inhalable dust, a sampling head such as the IOM collects the inhalable fraction onto a weighed filter.

Built into Aethair PRO and Aethair IAQ2

Measured by the monitor's own sensors, calibrated before it ships: nothing to add.

An instrument on Thiamis4

A third-party instrument connected to a Thiamis gateway, reporting into the same Environet account.

Placing total PM monitoring

For nuisance and boundary work, place monitors along the site perimeter on the sides nearest sensitive receptors, with intakes clear of local dust sources, and always record wind speed and direction so a dust event can be attributed to on-site activity rather than a passing source. For occupational inhalable dust, the sampling head sits in the worker's breathing zone to capture the actual inhaled exposure over the shift.

Every device and option that measures Total PM / Mass Conc. 6

Device / optionTypeBase platformMeasures
Aethair PRO built-in sensors
Built-in sensors
Aethair PRO
Aethair IAQ built-in sensors
Built-in sensors
Aethair IAQ
Thermo Scientific · pDR-1500, ADR-1500
Particulate & Dust Monitors
Thiamis
TSI · DustTrak 8530, DustTrak 8530EP, DustTrak 8532…
Particulate & Dust Monitors
Thiamis
Total PM / Mass Conc.PM1PM10PM2.5PM4 (Respirable)
Met One · ES-642
Particulate & Dust Monitors
Thiamis
Total PM / Mass Conc.
Trolex · Air XD (TX8005), Air XD (TX8015), XD ONE (TX8060)…
Particulate & Dust Monitors
Thiamis

Configure Total PM / Mass Conc. Monitoring

Where it is monitored

Solutions That Monitor Total PM / Mass Conc.

Each one links to the solution page showing what that industry measures it for.

Article Library

Reading on Total PM / Mass Conc.

All articles

Related

Questions

Total PM / Mass Conc. FAQ

What is the difference between total PM, PM10, and PM2.5?

Total PM (TSP) is the whole suspended mass across all sizes; PM10 is only the fraction up to ten microns and PM2.5 only up to 2.5. In other words PM10 and PM2.5 are defined slices of the total, chosen because they match how far particles penetrate the body. Total PM is broader and coarser, and is used for general dust burden rather than a specific health fraction.

Is total dust regulated?

In the workplace, yes: many low-toxicity dusts without a more specific standard are controlled through an inhalable or total-dust limit, expressed as a shift average. In ambient air, most modern frameworks regulate PM10 and PM2.5 rather than TSP, so outdoor total PM is more often a nuisance and permit metric set locally.

Why measure total PM instead of just PM2.5 and PM10?

Total PM answers a different question: how much dust in total is being generated or deposited, regardless of size. For deposition complaints, general housekeeping dust, and low-toxicity bulk materials, the total burden is the relevant figure, whereas PM2.5 and respirable dust target specific health fractions. Many sites monitor both.

How do I monitor total PM?

The Aethair family reports PM1, PM2.5, and PM10 mass from a built-in optical sensor, which covers the suspended mass up to its inlet range for most practical purposes. For a true TSP figure or an occupational inhalable-dust result, a Thiamis gateway can carry a high-volume or gravimetric sampler. Use the configurator to combine total PM with PM10, PM2.5, and noise in a dust-monitoring configuration.

Monitor Total PM / Mass Conc. on the Record

Schedule a callConfigure Total PM / Mass Conc. Monitoring All parameters

A 30-minute call: you tell us about your application, then we demo the solution for it.