Compliance · United States Pharmacopeia

USP General Chapter <797>: pharmaceutical compounding, sterile preparations

Indoor: sterile compounding pharmacies (USA)

USP General Chapter <797>, Pharmaceutical Compounding — Sterile Preparations, sets the standards for compounding sterile medications, in a revision that became official on November 1, 2023. Its facility requirements are built on the ISO 14644-1 cleanliness classes. The primary engineering control where compounding happens operates at ISO Class 5 (3,520 particles/m³ at ≥0.5 µm). It sits inside an ISO Class 7 buffer room (352,000 particles/m³) with at least 30 air changes per hour, held at a positive pressure of at least 0.020 inches of water column (about 5 Pa) relative to adjacent, less clean areas. Relative humidity in compounding areas is held at 60 % or below.

Schedule a callConfigure USP 797 Monitoring

Limit values

USP 797 Limit Values

Every value United States Pharmacopeia publishes for the 3 parameters below, with its averaging period, as the standard states it.

Differential Pressure Meteorology
5 Pa Minimum, buffer room (positive)0.020 in. w.c. relative to adjacent less clean areas
Particle Count (by size) Particulate Matter
3520 particles/m³ ISO Class 5 primary engineering control, ≥0.5 µm
352000 particles/m³ ISO Class 7 buffer room, ≥0.5 µm
Relative Humidity Meteorology
60 % Maximum, compounding areas

Who it applies to

Who Must Comply

Pharmacies, hospitals, outsourcing facilities, and clinics that compound sterile preparations in the United States, as enforced by state boards of pharmacy and accreditors. Hazardous drugs add the requirements of USP <800>.

Monitoring

How Monitoring Demonstrates Compliance

Classification and certification are periodic: certified particle counts and airflow tests at set intervals, following ISO 14644. What has to be shown continuously is the pressure relationship, which the chapter expresses as a number, with temperature and humidity recorded alongside. A continuous record with alarms shows the cascade held between certifications and flags a door, filter, or fan problem when it happens.

Recommended

best match
3 of 3 covered · 1 monitor
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Built-inRelative HumidityParticle Count (by size)

    Gas 1

    Free: one more gas sensor cartridge

    Gas 2

    Free: one more gas sensor cartridge

    MultiSense

    Free: a MultiSense, stock or built to order

    Expansion

    Aethair Diff. Pressure

    Differential Pressure

    A gauge sensor reads 0–10 kPa, with the higher-pressure side connected to its port.

    Also measures 11 more
    Dew PointHeat IndexIlluminance / LightPM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Differential PressureDiff. Pressure cartridge——
Particle Count (by size)Built inBuilt in1 instrument via Thiamis
Relative HumidityBuilt inBuilt in12 instruments via Thiamis

Devices

Devices That Cover USP 797

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers part of it (combine on one Thiamis)

Solutions

Solutions Judged Against USP 797

All solutions

Article Library

Articles on USP 797

All articles

Questions

USP 797 FAQ

What pressure differential does USP 797 require?

At least 0.020 inches of water column (about 5 Pa) positive pressure in the buffer room relative to adjacent, less clean areas.

What ISO classes does USP 797 use?

ISO Class 5 for the primary engineering control where compounding takes place, inside an ISO Class 7 buffer room, as defined by ISO 14644-1.

What humidity does USP 797 call for?

Relative humidity in compounding areas held at 60 % or below.

Monitor Against USP 797

Schedule a callBuild a Configuration All standards

A 30-minute call: you tell us about your application, then we demo the solution for it.