ISO 14644-1: cleanroom classification by particle concentration

Indoor: cleanrooms and controlled environments

ISO 14644-1, Cleanrooms and associated controlled environments — Classification of air cleanliness by particle concentration, defines cleanroom classes by the maximum number of particles per cubic meter at given sizes. At ≥0.5 µm, the limits are 3,520 particles/m³ for ISO Class 5, 35,200 for Class 6, 352,000 for Class 7, and 3,520,000 for Class 8: each class allows ten times the particles of the one below. The current edition is from 2015.

Schedule a callConfigure ISO 14644-1 Monitoring

The standard

What ISO 14644-1 Is

Other standards build on it: USP <797> for sterile compounding (ISO Class 5 and 7), ASHRAE's data center guidance (ISO Class 8), EU GMP grades for pharmaceutical manufacturing, and LEED v5, which accepts ISO Class 8 as an alternative particulate result.

Limit values

ISO 14644-1 Limit Values

Every value ISO publishes for the parameter below, with its averaging period, as the standard states it.

Particle Count (by size) Particulate Matter
3520 particles/m³ ISO Class 5, ≥0.5 µm
35200 particles/m³ ISO Class 6, ≥0.5 µm
352000 particles/m³ ISO Class 7, ≥0.5 µm
3520000 particles/m³ ISO Class 8, ≥0.5 µm

Who it applies to

Who Uses It

Anyone who has to show a space meets a cleanliness class: pharmaceutical and biotechnology manufacturing, semiconductor and electronics fabrication, medical device production, hospital pharmacies, laboratories, and data centers.

Monitoring

How Monitoring Demonstrates Compliance

Classifying a room means counting particles at defined sampling locations with an optical particle counter calibrated to ISO 21501-4, following the sampling plan in the standard. Ongoing monitoring against the class follows ISO 14644-2. Continuous particle trends between classifications show when a room drifts, alongside the pressure cascade, temperature, and humidity that keep it in class.

Recommended

best match
1 of 1 covered · 1 monitor
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Built-inParticle Count (by size)

    Gas 1

    Free: one more gas sensor cartridge

    Gas 2

    Free: one more gas sensor cartridge

    MultiSense

    Free: a MultiSense, stock or built to order

    Expansion

    Free: differential pressure

    Also measures 12 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightPM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air Temperature

Alternative

Aethair IAQ
1 of 1 covered · 1 monitor
  1. Aethair IAQ built-in sensors

    Compact plug-in monitor with every sensor built in, nothing to add. Ideal for straightforward indoor air quality monitoring.

    Built-inParticle Count (by size)
    Also measures 12 more
    Formaldehyde (CH₂O)Carbon Dioxide (CO₂)Dew PointHeat IndexRelative HumidityPM1PM10PM2.5Total PM / Mass Conc.Barometric PressureAir TemperatureVOC (Total)

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Particle Count (by size)Built inBuilt in1 instrument via Thiamis

Devices

Devices That Cover ISO 14644-1

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers it on its own

Solutions

Solutions Judged Against ISO 14644-1

All solutions

Article Library

Articles on ISO 14644-1

All articles

Questions

ISO 14644-1 FAQ

What are the ISO 14644-1 cleanroom class limits?

At ≥0.5 µm: 3,520 particles/m³ for ISO Class 5, 35,200 for Class 6, 352,000 for Class 7, and 3,520,000 for Class 8.

What instrument classifies a cleanroom?

An optical particle counter calibrated to ISO 21501-4, used at the sampling locations and volumes the standard sets.

Which standards refer to ISO 14644-1 classes?

Among others, USP 797 for sterile compounding, ASHRAE's data center guidance, and LEED v5.