Compliance · California Air Resources Board

CARB Indoor Air Cleaning Device Regulation (17 CCR §94800–94810)

Indoor: ozone emitted by air cleaning devices (California)

The California Air Resources Board regulation on indoor air cleaning devices, 17 CCR §94800 et seq., limits the ozone that air cleaners may produce. Since 2010, any indoor air cleaning device manufactured for use, sold, or supplied in California must be certified by CARB to produce an ozone emission concentration not exceeding 0.050 ppm, tested under the regulation's procedure, and labeled accordingly. It covers ionizers, electrostatic precipitators, photocatalytic oxidation and UV devices, and corona discharge generators; intentional ozone generators marketed as air purifiers cannot be certified.

Schedule a callConfigure CARB Air Cleaner Monitoring

Limit values

CARB Air Cleaner Limit Values

Every value California Air Resources Board publishes for the parameter below, with its averaging period, as the standard states it.

Ozone (O₃) Gases & VOCs
0.05 ppm Certified emission concentrationtested per section 94805; devices sold in California must be certified

Who it applies to

Who It Applies to

Manufacturers, distributors, and retailers of indoor air cleaning devices sold in or shipped to California, and indirectly every building owner choosing an air cleaner there. Certified devices are listed by CARB.

Monitoring

How Monitoring Relates to It

The limit is a certification test of the device, not an indoor air limit, so a room reading is not a compliance test. Measuring ozone in the space still shows whether an air cleaner, a printer, or outdoor infiltration is adding ozone, and whether indoor levels stay low against the occupational and indoor guidance values.

Recommended

best match
1 of 1 covered · 1 monitor
  1. Aethair PRO

    Industrial monitor for indoor and outdoor sites. Built-in sensors cover the essentials, and hot-swappable gas sensor cartridges and a differential-pressure option add more.

    Gas 1

    Aethair O₃+NO₂

    Ozone (O₃)

    Four-electrode electrochemical sensing measures oxidizing gases (ozone plus nitrogen dioxide) and reports one…

    Gas 2

    Free: one more gas sensor cartridge

    MultiSense

    Free: a MultiSense, stock or built to order

    Expansion

    Free: differential pressure

    Also measures 14 more
    Dew PointHeat IndexRelative HumidityIlluminance / LightParticle Count (by size)PM1PM10PM2.5Total PM / Mass Conc.Barometric PressureEquivalent Continuous Level (Leq)Sound Pressure Level (SPL)Air TemperatureNitrogen Dioxide (NO₂)

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
Ozone (O₃)O₃+NO₂ cartridge—1 instrument via Thiamis

Devices

Devices That Cover CARB Air Cleaner

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Aethair monitors

Covers it on its own

Solutions

Solutions Judged Against CARB Air Cleaner

All solutions

Article Library

Articles on CARB Air Cleaner

All articles

Questions

CARB Air Cleaner FAQ

What ozone limit does CARB set for air cleaners?

An ozone emission concentration of no more than 0.050 ppm, verified by CARB certification testing before the device can be sold in California.

Which devices does the CARB regulation cover?

Indoor air cleaning devices including ionizers, electrostatic precipitators, photocatalytic oxidation and UV devices, and corona discharge generators.

Is the CARB limit an indoor air standard?

No. It is a device certification limit on emissions, not a limit on ozone in a room.

Monitor Against CARB Air Cleaner

Schedule a callBuild a Configuration All standards

A 30-minute call: you tell us about your application, then we demo the solution for it.