Sensors · Noise Monitors

Cirrus Research Noise Monitors

Cirrus Research Optimus and Optimus+ handheld sound level meters are integrating, data-logging instruments that measure SPL, Leq, Peak, and statistical Ln to IEC 61672 Class 1 or Class 2. The environmental models add real-time 1/1 and 1/3 octave-band analysis. The 15x, 16x, and 17x families are the basic, occupational, and environmental tiers, and the third digit sets the class (1 is Class 2, 2 is Class 1).

Schedule a callBuild a Configuration

Measures

What Cirrus Research Noise Monitors Measure

4 parameters, each linked to its page: the sensors, units, and standards behind it.

Models

Cirrus Research Noise Monitors Models

20 models, each with what it measures and the ranges its datasheet gives.

ModelDescriptionMeasures & specs
151BOptimus+ Industrial (Red) Class 2 sound level meter: sound pressure level with A/C/Z weightings and Max/Min; SPL only, no Leq or octave bands.
152BOptimus+ Industrial (Red) Class 1 sound level meter: sound pressure level with A/C/Z weightings and Max/Min; SPL only, no Leq or octave bands.
151APrevious-generation Optimus Class 2 sound level meter (SPL only); superseded by the 151B.
152APrevious-generation Optimus Class 1 sound level meter (SPL only); superseded by the 152B.
161BOptimus+ Industrial (Red) Class 2 occupational sound level meter that adds integrating Leq and Peak (with on-device TWA / dose); no octave bands.
162BOptimus+ Industrial (Red) Class 1 occupational sound level meter that adds integrating Leq and Peak (with on-device TWA / dose); no octave bands.
161COptimus+ Industrial (Red) Class 2 occupational sound level meter with real-time 1/1 octave bands and NR/NC curves; SPL, Leq, and Peak.
162COptimus+ Industrial (Red) Class 1 occupational sound level meter with real-time 1/1 octave bands and NR/NC curves; SPL, Leq, and Peak.
161APrevious-generation Optimus Red Class 2 occupational meter (SPL, Leq, Peak); superseded by the 161B.
162APrevious-generation Optimus Red Class 1 occupational meter (SPL, Leq, Peak); superseded by the 162B.
161DPrevious-generation Optimus Red Class 2 occupational meter (SPL, Leq, Peak); no longer in the current Cirrus catalog.
162DPrevious-generation Optimus Red Class 1 occupational meter (SPL, Leq, Peak); no longer in the current Cirrus catalog.
1710Optimus+ Environmental (Green) Class 2 sound level meter: SPL, Leq, Peak, and statistical Ln (e.g. L10, L90). Base model, without octave bands.
1720Optimus+ Environmental (Green) Class 1 sound level meter: SPL, Leq, Peak, and statistical Ln (e.g. L10, L90). Base model, without octave bands.
171AOptimus+ Environmental (Green) Class 2 environmental sound level meter with real-time 1/1 octave bands and NR/NC curves; SPL, Leq, Peak, and statistical Ln.
172AOptimus+ Environmental (Green) Class 1 environmental sound level meter with real-time 1/1 octave bands and NR/NC curves; SPL, Leq, Peak, and statistical Ln.
171COptimus+ Environmental (Green) Class 2 sound level meter; the top tier adds real-time 1/1 and 1/3 octave bands, tonal-noise detection, and up to 28 statistical Ln values.
172COptimus+ Environmental (Green) Class 1 sound level meter; the top tier adds real-time 1/1 and 1/3 octave bands, tonal-noise detection, and up to 28 statistical Ln values.
171BPrevious-generation Optimus Green Class 2 environmental meter (SPL, Leq, Peak, Ln); superseded by the 171C.
172BPrevious-generation Optimus Green Class 1 environmental meter (SPL, Leq, Peak, Ln); superseded by the 172C.

Standards

Standards for What It Measures

Standards that set limits on the parameters it reports, plus any method standard the instrument is built to.

Solutions

Where Cirrus Research Noise Monitors Are Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

On the platform

What Cirrus Research Noise Monitors Get From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

Similar

Other Noise Monitors

Questions

Cirrus Research Noise Monitors FAQ

What do the Cirrus Optimus model numbers mean?

The family digits set the tier: 15x is the basic sound level meter (SPL only), 16x the occupational / industrial meter (adds Leq, Peak, and integrating TWA / dose), and 17x the environmental meter (adds statistical Ln such as L10 and L90). The final digit is the IEC 61672 class: a code ending in 1 (e.g. 161, 171, 1710) is Class 2 and one ending in 2 (e.g. 162, 172, 1720) is Class 1. A trailing letter marks the feature tier: A adds real-time 1/1 octave bands, C adds 1/1 and 1/3 octave bands with tonal-noise detection.

Which Optimus noise metrics does the integration read?

The broadband levels: sound pressure level (LAF/LAS/LAI and LCF/LCS/LCI: A/C/Z weightings in Fast, Slow, and Impulse), equivalent continuous level Leq (LAeq/LCeq/LZeq), peak level (LApeak/LCpeak/LZpeak), and, on the 17x environmental models, the statistical level L90. The basic 15x meters report SPL only; the 16x and 17x models add Leq and Peak.

The Optimus measures 1/1 and 1/3 octave bands. Are those brought into the platform?

Not by default. The 171A/172A and the Red 161C/162C add real-time 1/1 octave bands, and the 171C/172C environmental models add 1/3 octave bands with tonal-noise detection. The integration reads the broadband A/C/Z levels (SPL, Leq, Peak, Ln) rather than the per-band octave spectra, which the meter also stores for download in Cirrus NoiseTools. Octave-band data is exposed by the meter's interface (10 bands for 1/1 octave, 31.5 Hz–16 kHz; 36 for 1/3 octave, 6.3 Hz–20 kHz) and can be enabled where a deployment needs it.

How does the Optimus connect to the logger?

Over a serial link at 115200 baud. The logger runs an identify (IDN) handshake to read the meter's model code and serial number, then polls it for the live noise levels at the logging interval. Class 1 meters use the MK:224 microphone, Class 2 meters the MK:216.

Sources: cirrusresearch.com · cirrusresearch.com · cirrusresearch.com · cirrusresearch.com · cirrusresearch.com

Bring the Cirrus Research Noise Monitors Into Environet

Schedule a callBuild a Configuration All sensors How Thiamis connects it

A 30-minute call: you tell us about your application, then we demo the solution for it.