Sensors · Heat Stress & Comfort

TSI QUESTemp

Heat Stress & Comfort

TSI Quest QUESTemp° area heat-stress (WBGT) monitors. Models 32/34/36 pair a natural (water) wet-bulb with dry-bulb, globe, and relative-humidity sensors; 44/46/48N drop the wick for a waterless wet-bulb (RH sensor + proprietary algorithm). All compute indoor/outdoor WBGT and a heat index / HUMIDEX, log over RS-232 to Detection Management Software, and accept an optional Head-Torso-Ankle tri-sensor array for height-weighted WBGT.

Schedule a callBuild a Configuration

Measures

What the TSI QUESTemp Measures

5 parameters, each linked to its page: the sensors, units, and standards behind it.

Models

TSI QUESTemp Models

7 models, each with what it measures and the ranges its datasheet gives.

ModelDescriptionMeasures & specs
QuestTemp-32Entry-level natural (water) wet-bulb area WBGT monitor without data logging, a replacement for the WIBGET WB-300. Dry-bulb, natural wet-bulb, globe, and relative-humidity sensors; computes indoor and outdoor WBGT plus a heat index / HUMIDEX.
QuestTemp-34Natural (water) wet-bulb area WBGT monitor with data logging. Dry-bulb, natural wet-bulb, globe, and relative-humidity sensors; computes indoor and outdoor WBGT plus a heat index / HUMIDEX.
QuestTemp-36Logging natural wet-bulb monitor that adds selectable stay-time work/rest limits: ACGIH Heat-Stress TLV, U.S. Navy PHEL, Navy/Marine Ashore Flag, and EPRI action limits.
QuestTemp-38Discontinued natural wet-bulb logging model, no longer in the current TSI catalog; retained for units still in the field.
QuestTemp-44Entry waterless wet-bulb monitor: an RH sensor and proprietary algorithm replace the wick, so there is no daily maintenance. Reports outdoor WBGT only (no indoor WBGT, heat index, stay times, or tri-sensor option), with data logging.
QuestTemp-46Waterless wet-bulb monitor with indoor and outdoor WBGT, heat index / HUMIDEX, and selectable stay-time limits (including EPRI action limits); accepts the tri-sensor array.
QuestTemp-48NTop waterless wet-bulb monitor: adds an event-logging mode and a D-ring hands-free lanyard mount. Stay-time set covers ACGIH Heat-Stress TLV, U.S. Navy PHEL, and Ashore Flag conditions (EPRI action limits excluded).

Standards

Standards for What It Measures

Standards that set limits on the parameters it reports, plus any method standard the instrument is built to.

Solutions

Where the TSI QUESTemp Is Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

On the platform

What the TSI QUESTemp Gets From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

Similar

Other Heat Stress & Comfort

Questions

TSI QUESTemp FAQ

What is the difference between the natural wet-bulb (32/34/36) and waterless (44/46/48N) QUESTemp models?

The 32/34/36 use a traditional wet-bulb sensor (a wick kept wet with distilled water) to read the natural wet-bulb temperature directly. The 44/46/48N drop the wick: a relative-humidity sensor feeds a proprietary algorithm that derives the wet-bulb value, so there is no daily water top-up or wick maintenance. Both routes yield the same WBGT index.

Which parameters does the QUESTemp measure?

Every unit carries dry-bulb, globe, and relative-humidity sensors (plus a natural wet-bulb sensor on the 34/36). From these it computes the Wet Bulb Globe Temperature (an indoor WBGTi and an outdoor WBGTo index) and a heat index / HUMIDEX. The QUESTemp does not measure air velocity.

What is the Head-Torso-Ankle weighted WBGT option?

ISO 7243 weights WBGT measured at three heights for a standing worker: ankle, abdomen (torso), and head. With the optional tri-sensor array the QUESTemp reads three sensor bars at once (the S1/S2/S3 channels) and reports the height-weighted average WBGT. A remote sensor bar can sit up to ~61 m (200 ft) from the unit on a cable.

How does the Thiamis integration read a QUESTemp?

Over the RS-232 serial port at 9600 baud (8-N-1) using the QUESTemp command protocol (checksummed QA/QF/QB/QC queries). The driver identifies the model from the QA response, then polls each enabled sensor bar for its dry-bulb, wet-bulb, globe, humidity, WBGT, and heat-index values.

Why does the QUESTemp° 44 report fewer values than the 46/48N?

The 44 is the entry waterless model. It reports the outdoor WBGT index only (no indoor WBGT, heat index, or stay-time work/rest limits) and does not accept the tri-sensor array. The 46 adds indoor WBGT, heat index, and stay times; the 48N adds an event-logging mode and a hands-free D-ring mount.

Sources: tsi.com · tsi.com · tsi.com

Bring the TSI QUESTemp Into Environet

Schedule a callBuild a Configuration All TSI devices All sensors How Thiamis connects it

A 30-minute call: you tell us about your application, then we demo the solution for it.