Compliance · US MSHA

MSHA Occupational Noise Exposure (30 CFR Part 62)

Occupational: mines (USA), hearing conservation

The US Mine Safety and Health Administration's noise standard, 30 CFR Part 62, protects miners' hearing. It sets a permissible exposure level of 90 dBA as an 8-hour time-weighted average (a dose of 100 %), an action level of 85 dBA (a dose of 50 %) that requires enrollment in a hearing conservation program, and a ceiling: no miner may be exposed at any time to sound levels above 115 dBA. Doses use a 5 dB exchange rate.

Schedule a callConfigure MSHA noise Monitoring

Limit values

MSHA noise Limit Values

Every value US MSHA publishes for the 2 parameters below, with its averaging period, as the standard states it.

TWA / Noise Dose Noise
90 dBA 8-hour TWA (PEL)5 dB exchange rate; integrates 90 to at least 140 dBA
85 dBA 8-hour TWA (action level)hearing conservation program; integrates 80 to at least 130 dBA
Max Level (Lmax) Noise
115 dBA Ceiling (at any time)without adjustment for hearing protectors

Who it applies to

Who Must Comply

Operators of US coal and metal and nonmetal mines, for every miner exposed to noise on a work shift.

Monitoring

How Monitoring Demonstrates Compliance

Exposure is determined with a dosimeter or sound level meter integrating the levels the standard specifies over the shift. Above the permissible exposure level the operator must use feasible engineering and administrative controls; continuous noise monitoring at fixed points shows where and when levels rise, which is where those controls go.

Recommended

best match
2 of 2 covered · 1 gateway · 1 instrument
  1. Thiamis connects 1 instrument

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

    • TSI Noise Monitors

      Max Level (Lmax)TWA / Noise Dose

      TSI Quest SoundPro SE/DL Class 1 and Class 2 integrating sound level meters and real-time analyzers measure broadband…

      Connects over RS-232 (ASCII)

    Also measures 5 more
    Average Level (Lavg)Equivalent Continuous Level (Leq)Min Level (Lmin)Peak Level (Lpeak)Sound Pressure Level (SPL)

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
TWA / Noise Dose——1 instrument via Thiamis
Max Level (Lmax)——1 instrument via Thiamis

Devices

Devices That Cover MSHA noise

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Covers both on its own

Solutions

Solutions Judged Against MSHA noise

All solutions

Questions

MSHA noise FAQ

What is the MSHA noise limit?

A permissible exposure level of 90 dBA as an 8-hour time-weighted average, with an action level of 85 dBA and no exposure at any time above 115 dBA.

How does MSHA's noise standard differ from OSHA's?

Both use a 90 dBA permissible level, an 85 dBA action level, and a 5 dB exchange rate; MSHA's applies to mines, OSHA's (29 CFR 1910.95) to general industry.

What happens at the MSHA action level?

A miner whose exposure reaches the 85 dBA action level must be enrolled in a hearing conservation program.

Monitor Against MSHA noise

Schedule a callBuild a Configuration All standards

A 30-minute call: you tell us about your application, then we demo the solution for it.