Compliance · US OSHA 1910.1028

OSHA Benzene Standard (29 CFR 1910.1028)

Occupational: benzene (USA)

OSHA's benzene standard, 29 CFR 1910.1028, sets the legal exposure limits for benzene: a permissible exposure limit of 1 ppm as an 8-hour time-weighted average, a short-term exposure limit of 5 ppm over any 15-minute period, and an action level of 0.5 ppm (8-hour TWA) that triggers periodic monitoring and medical surveillance. Benzene is a human carcinogen that causes leukemia, so the standard adds regulated areas, engineering controls, respirators, and medical surveillance to the limits.

Schedule a callConfigure OSHA benzene Monitoring

Limit values

OSHA benzene Limit Values

Every value US OSHA 1910.1028 publishes for the parameter below, with its averaging period, as the standard states it.

BTEX / speciated VOC Gases & VOCs
1 ppm 8-hour TWA (PEL)benzene
5 ppm STELbenzene, 15-minute
0.5 ppm Action levelbenzene, 8-hour TWA

Who it applies to

Who Must Comply

Employers where workers handle benzene or products containing it: petroleum refining, petrochemical and chemical manufacturing, bulk terminals and fuel distribution, tire and rubber manufacturing, and laboratories. Construction work falls under 29 CFR 1926.1128, which refers to the same requirements.

Monitoring

How Monitoring Demonstrates Compliance

Compliance rests on exposure monitoring representative of each employee's 8-hour and 15-minute exposure, repeated periodically at or above the action level; speciated benzene is measured by laboratory analysis of personal samples or by gas chromatography. Continuous area monitoring for total VOCs gives early warning of a release, and a speciated analyzer shows whether the rise is benzene. NIOSH recommends 0.1 ppm, ten times lower than the PEL.

Recommended

best match
1 of 1 covered · 1 gateway · 1 instrument
  1. Thiamis connects 1 instrument

    A gateway that connects the third-party instruments you choose to the Aethair Platform.

Customize this configuration

Who measures each parameter

Parameter Aethair PRO Aethair IAQ External
BTEX / speciated VOC——1 instrument via Thiamis

Devices

Devices That Cover OSHA benzene

How much of this standard one Aethair monitor covers, followed by the third-party instruments in the sensor catalog that measure its parameters. Each connects to Environet through a Thiamis gateway, which adds whatever the monitor leaves out.

Covers it on its own

Solutions

Solutions Judged Against OSHA benzene

All solutions

Article Library

Articles on OSHA benzene

All articles

Questions

OSHA benzene FAQ

What is the OSHA PEL for benzene?

1 ppm as an 8-hour time-weighted average, with a short-term exposure limit of 5 ppm over any 15-minute period and an action level of 0.5 ppm.

Can a total VOC sensor measure benzene?

Not selectively. A total VOC reading shows that organic vapors rose; benzene itself needs a speciated measurement, such as gas chromatography or laboratory analysis of a sample.

What does NIOSH recommend for benzene?

A recommended exposure limit of 0.1 ppm as a time-weighted average and 1 ppm as a short-term limit, stricter than OSHA's.

Monitor Against OSHA benzene

Schedule a callBuild a Configuration All standards

A 30-minute call: you tell us about your application, then we demo the solution for it.