Sensors · Water Quality Sondes

Spectra Scientific Spectra Litmus

Water Quality Sondes

Spectra Scientific (spectrascientific.com) Spectra Litmus configurable multiparameter water-quality sonde (Litmus 6 and Litmus 4), read over Modbus RS-485. A central wiper plus interchangeable titanium smart-sensor ports measure water pressure/level and temperature, conductivity, specific conductance, salinity, TDS, density and resistivity, pH/ORP, turbidity/TSS, optical dissolved oxygen, chlorophyll, blue-green algae, and fDOM, plus a broad ion-selective-electrode panel (chloride, ammonium, ammonia, nitrate, and metal/halide ISEs) and barometric pressure. Now withdrawn from the vendor's catalog in favor of resold YSI EXO sondes.

Schedule a callBuild a Configuration

Measures

What the Spectra Scientific Spectra Litmus Measures

23 parameters, each linked to its page: the sensors, units, and standards behind it.

Models

Spectra Scientific Spectra Litmus Models

2 models, each with what it measures and the ranges its datasheet gives.

ModelDescriptionMeasures & specs
Spectra Litmus 6Flagship configurable sonde: a central wiper plus five interchangeable titanium smart-sensor ports. Carries the full water-quality suite (temperature, conductivity/specific conductance/salinity/TDS, pH/ORP, turbidity/TSS, optical dissolved oxygen, chlorophyll and blue-green algae, fDOM, and the ion-selective electrodes), read over Modbus RS-485, so the parameter set follows whichever sensors are fitted. Bluetooth or wired handheld; up to ~144 days on four D-cell batteries. Withdrawn from the vendor's current catalog.
Spectra Litmus 4Compact sonde: a central wiper plus a smaller bank of interchangeable titanium smart-sensor ports for the same core water-quality parameters, with fewer sensors deployed at once than the six-position Litmus 6. Same Modbus read-out and Bluetooth/wired handheld options. Withdrawn from the vendor's current catalog.

Standards

Standards for What It Measures

Standards that set limits on the parameters it reports.

Solutions

Where the Spectra Scientific Spectra Litmus Is Used

Solutions whose recommended configuration uses this instrument or whose standards it is built to, followed by solutions whose core panel it partly measures.

On the platform

What the Spectra Scientific Spectra Litmus Gets From Aethair

Connected through Thiamis, its readings arrive in the same Environet account as Aethair's own monitors.

Similar

Other Water Quality Sondes

Questions

Spectra Scientific Spectra Litmus FAQ

What is the Spectra Litmus and how does the integration read it?

The Spectra Litmus is Spectra Scientific's configurable multiparameter sonde: a central wiper plus interchangeable titanium smart-sensor ports (five on the Litmus 6, fewer on the Litmus 4). The Thiamis driver reads it over Modbus RS-485 (9600 8-N-1), polling the full register map every interval. Because it is a configurable smart-sensor sonde, the parameters that actually return values depend on which sensors are fitted to that particular unit.

Is the pressure reading water pressure or barometric pressure?

Both are reported, as separate parameters. Water Pressure (kPa) is the submerged pressure/depth sensor, from which Water Level (m) is also derived; Barometric Pressure (kPa) comes from the sonde's own barometer and compensates the vented level. A third internal 'zero atmospheres' reference is a calibration value rather than a measured parameter, so it is not ingested.

Which parameters does the single Ion-Selective (Other Ions) entry cover?

Chloride, ammonium, ammonia, and nitrate each have their own parameter. The remaining ion-selective electrodes the driver can read (silver, sulfide, fluoride, bromide, iodide, cadmium, lead, potassium, copper (cupric), calcium, cyanide, total nitrogen, and oil-in-water) are folded into the single Ion-Selective (Other Ions) parameter, since a Litmus is rarely fitted with more than one or two of them at a time.

Why do pH, dissolved oxygen, and the algae parameters show two units each?

pH is reported both as pH units and as the raw electrode signal in millivolts. Dissolved oxygen is reported both as concentration (mg/L) and as saturation (%). Chlorophyll and blue-green algae are each reported both as a concentration (µg/L) and as a cell count (pcs/L).

What are the Density and Resistivity readings?

They are conductivity-derived water properties the sonde computes: water density (g/L) and specific resistance / resistivity (MΩ·cm, the reciprocal of conductivity). Both are standard outputs of research-grade sondes (the In-Situ Aqua TROLL and YSI EXO report the same quantities) and are ingested here as their own parameters.

Is the Spectra Litmus still sold?

No. Spectra Scientific has withdrawn its own-brand Litmus 6 and Litmus 4 sondes from its current catalog and now resells YSI EXO sondes for multiparameter monitoring. The Thiamis integration is retained for existing Litmus deployments; 'integrated' here refers to integration status, not product availability.

Sources: spectrascientific.com